26
Adjustment of minimum level
Oven burner
Remove the top pan support as well as the
burner caps and the burner crowns.
Unscrew and remove the 2 top plate-fixing
screws and remove the top plate.
Light the burner knob in the maximum
position and leave the oven door closed for
about 10 mins.
Turn the knob slowly to the minimum position.
Pull off the knob to adjust minimum flow.
Unscrew or screw the by-pass screw until a
regular small flame is reached.
For LPG completely tighten the by-pass screw
The flame shouldn’t extinguish when closing the
oven door.
Grill burner
The grill temperature cannot be adjusted. To
obtain a lower temperature or slower cooking
time the grill pan must be lowered away from the
flame.
After completion of any repairs,
conversion or adjustments, the statutory
safety tests must be carried out.
by-pass