Adjustment of minimum level

Oven burner

Remove the top pan support as well as the burner caps and the burner crowns.

Unscrew and remove the 2 top plate-fixing screws and remove the top plate.

Light the burner knob in the maximum position and leave the oven door closed for about 10 mins.

Turn the knob slowly to the minimum position.

Pull off the knob to adjust minimum flow.

Unscrew or screw the by-pass screw until a regular small flame is reached.

For LPG completely tighten the by-pass screw

The flame shouldn’t extinguish when closing the oven door.

Grill burner

The grill temperature cannot be adjusted. To obtain a lower temperature or slower cooking time the grill pan must be lowered away from the flame.

After completion of any repairs, conversion or adjustments, the statutory safety tests must be carried out.

by-pass

26

Page 26
Image 26
Tricity Bendix SG 210 manual Adjustment of minimum level