Specifications

 

The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.

 

 

 

 

 

 

 

 

 

 

 

 

Model:

SMART500RT1U

SMART750RM1U

SMART1000RM1U

SMART1000RM2U

 

 

 

Series #:

AGSM52SRM1U

AGSM7501UPC

AGSM10001UPC

AGSU1022U31

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

Nominal Voltage/Frequency:

120VAC/60 Hz

120VAC/60 Hz

120VAC/60 Hz

120VAC/60 Hz

 

 

 

Recommended Dedicated

 

 

 

 

 

 

 

Electrical Circuit:

15 amp

15 amp

15 amp

15 amp

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

Capacity (VA/Watts):

500/300

750/450

1000/640

1000/700

 

 

 

On Line Nominal Voltage/Waveform:

120VAC/sine wave

120VAC/sine wave

120VAC/sine wave

120VAC/sine wave

 

 

 

On Battery Nominal

 

 

 

 

 

 

 

Voltage/Waveform:

115VAC/PWM sine wave

120VAC/sine wave

120VAC/sine wave

120VAC/sine wave

 

 

 

Battery Runtime

 

 

 

 

 

 

 

(Half Load/Full Load) Minutes*:

14/4

24/7

25/10

21/9

 

 

 

Battery Recharge Time*:

2-4 hrs.

2-4 hrs.

2-4 hrs.

2-4 hrs.

 

 

 

FCC:

Class B

Class A

Class A

Class B

 

 

 

Approvals:

UL, cUL, NOM

UL, cUL, NOM

UL, cUL, NOM

UL, cUL, NOM

 

 

 

Model:

SMART1500RM2U

SMART1500RMXL2Ua

SMART2200RMXL2U

SMART2600RM2U

SMART3000RM2U

 

Series #:

AGSU1522U31

AGSU152XU31

AGSU2222U31

AGSU3022U31

AGSU3022U31

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

Nominal Voltage/Frequency:

120VAC/60 Hz

120VAC/60 Hz

120VAC/60 Hz

120VAC/60 Hz

120VAC/60 Hz

 

Recommended Dedicated

 

 

 

 

 

 

 

Electrical Circuit:

15 amp

15 amp

20 amp or 15 amp*

30 amp or 20 amp*

30 amp or 20 amp*

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

Capacity (VA/Watts):

1500/1000

1500/1000

2200/1600 *

2600/2100

3000/2250

 

 

 

 

 

(with 20 amp plug)

(with 30 amp plug)

(with 30 amp plug)*

 

 

 

 

1440/1307 *

2200/1787

2200/1787

 

 

 

 

 

(with 15 amp plug)

(with 20 amp plug)

(with 20 amp plug)*

 

On Line Nominal

 

 

 

 

 

 

 

Voltage/Waveform:

120VAC/sine wave

120VAC/sine wave

120VAC/sine wave

120VAC/sine wave

120VAC/sine wave

 

On Battery Nominal

 

 

 

 

 

 

 

Voltage/Waveform:

120VAC/sine wave

120VAC/sine wave

120VAC/sine wave

120VAC/sine wave

120VAC/sine wave

 

Battery Runtime (Half Load/

 

 

 

 

 

 

 

Full Load) Minutes*:

25/10

25/10+

20/8+

18/6+

13/4+

 

 

Battery Recharge Time*:

2-4 hrs.

2-4 hrs.

2-4 hrs.

2-4 hrs.

2-4 hrs.

 

 

FCC:

Class B

Class B

Class A

Class A

Class A

 

 

Approvals:

UL, cUL, NOM

UL, cUL, NOM

UL, cUL, NOM

UL, cUL, NOM

UL, cUL, NOM

 

ALL UNITS: Voltage-Regulated Output Voltage Range: ± 9%. On-Battery Output Voltage Range: ± 5 %. AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB at 1MHz); AC Protection Modes (H to N, H to G, N to G).

+Battery runtime can be extended with addition of optional Tripp Lite External Battery Packs (sold separately). SMART1500RMXL2Ua models use BP36V15-2U battery packs (limit one; not daisy- chain capable). SMART2200RMXL2U, SMART2600RM2U and SMART3000RM2U models can use either BP48V24-2U (limit one; not daisy-chain capable) or BP48V60RT3U (daisy-chain capable) battery packs. External batteries will increase both the battery runtime and the battery recharge time.

* Since these models include two plug options, the amperage of the recommended circuit would change to match the amperage of the plug. The output capacity would also change based on the plug type used. SMART2200RMXL2U features a 20-amp NEMA 5-20P plug attached to its line cord, but includes a 15-amp NEMA 5-15P plug loose in the box that can be attached to the line cord by a qualified electrician. SMART2600RM2U features a 20-amp NEMA 5-20P plug attached to its line cord, but includes a 30-amp twist-lock NEMA L5-30P plug loose in the box that can be attached to the line cord by a qualified electrician. SMART3000RM2U features a 30-amp twist-lock NEMA L5-30P plug attached to its line cord, but includes a 20-amp NEMA 5-20P plug loose in the box that can be attached to the line cord by a qualified electrician.

FCC RADIO/TV INTERFERENCE NOTICE: (FOR CLASS A MODELS)

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. Operation of this equipment is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

FCC RADIO/TV INTERFERENCE NOTICE: (FOR CLASS B MODELS)

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference using one or more of the following measures: reorient or relocate the receiving antenna; increase the separation between the equipment and the receiver; connect the equipment into an outlet on a circuit different from that which the receiver is connected; consult the dealer or an experienced radio/television technician for help. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC rules. Operation is subject to the following 2 conditions:

(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Note on Labeling

Two symbols are used on the label.

V~ : AC Voltage

V : DC Voltage

13

Page 14
Image 14
Tripp Lite 350, 525 owner manual Two symbols are used on the label ~ AC Voltage DC Voltage