Other UPS Features

AC Receptacles (Rear Panel)

These 230V IEC-320 receptacles provide your connected equipment with AC line power during normal operation and battery power during blackouts and brownouts. They also protect your equipment against damaging surges and line noise. You can remotely reboot connected equipment by turning receptacles OFF and ON using Tripp Lite PowerAlert software.

Circuit Breakers (Rear Panel)

These breakers will trip to prevent damage to your UPS due to overload. Two single-pole circuit breakers protect each 230V outlet bank and one double-pole circuit breaker protects the main input circuit bank that powers all the outlets. If a breaker trips, remove any overload then allow the UPS to cool before resetting the breaker.

"Smart" RS-232 Port (Lower Rear Panel)

This port, labeled “SMART LAN PRIMARY” or “LAN 4.1” on the UPS, connects your UPS to a workstation or server. Use with Tripp Lite software and cabling to monitor and manage network power and to automatically save open files and shut down equipment during power failures. This port uses RS-232 communications to transmit UPS and power conditions (Pin 7 = Transmit; Pin 8 = Common; Pin 9 = Receive). Contact Tripp Lite Customer Support for more information and a list of available SNMP, network management and connectivity products.

Contact Closure Ports (Lower Rear Panel)

These ports, labeled “LAN 2.2” on the Control Module, are also used to connect your UPS to a workstation or server. Use with Tripp Lite software and cabling to automatically save open files and shut down equipment during a blackout. This port uses contact-closure signals to indicate line-fail and low-battery status. Contact Tripp Lite Customer Support for more information.

Battery Connector (Rear Panel)

Use to connect Tripp Lite battery packs. Refer to the label next to the connector for the appropriate Tripp Lite battery pack to connect. Refer to instructions available with the battery pack for complete connection information and safety warnings.

Remote Control Interface Port (Lower Rear Panel)

Use to connect an optional RT-2 Remote Control Adapter to control the DataCenter via telephone or modem. Contact Tripp Lite for information about ordering the RT-2; refer to the RT-2 manual for operating instructions.

7

Page 7
Image 7
Tripp Lite Datacenter INT specifications Other UPS Features