Tripp Lite PVINT375 Troubleshooting, Specifications, Model, Output Power Maximum Continuous Watts

Models: PVINT375

1 20
Download 20 pages 8.34 Kb
Page 3
Image 3
Troubleshooting

Troubleshooting

Please check the following before sending the Inverter in for service:

Symptom

Problem

Correction

Alarm sounds.

Low battery voltage (<10.5 V).

Turn Inverter OFF and run engine to

 

 

recharge vehicle battery.

 

Output overload.

Turn Inverter OFF and remove overload by

 

 

unplugging high-wattage devices. Load

 

 

should not exceed your Inverter's maximum

 

 

continuous output power (see Specifications).

Inverter does not turn ON when

Automatic Inverter shutdown due

Turn Inverter OFF and run engine to

power switch is turned ON.

to low battery voltage (<10V).

recharge vehicle battery.

 

Automatic Inverter shutdown due

Turn Inverter OFF and remove overload by

 

to output overload.

unplugging high-wattage devices. Load

 

 

should not exceed your Inverter’s maximum

 

 

continuous output power (see Specifications).

 

Blown fuse.

Replace fuse with standard automotive fuse

 

 

of identical amperage (see Specifications).

Inverter is unable to power

Battery running low. Low battery

Turn Inverter OFF and run engine to

connected equipment.

voltage reduces Inverter power

recharge vehicle battery.

 

output.

 

 

Connected equipment load

Turn Inverter OFF and remove overload by

 

exceeds Inverter’s maximum

unplugging high-wattage devices. Load

 

continuous output power.

should not exceed your Inverter's maximum

 

 

continuous output power (see Specifications).

Connected equipment experiences

Loose connections.

Check and secure all connections.

audio/video distortion.

 

 

 

Audio/video interference.

Reposition equipment antennas and Inverter.

 

 

 

Specifications

Model:

PVINT375

Output Power (Maximum Continuous Watts)*:

375

Output Power (Peak Watts)**:

600

Input Voltage (DC):

12V nominal (10-15V)

Output Voltage (AC)/Frequency:

230V / 50 Hz. nominal

Output Waveform:

PWM Sine Wave

Low Battery Voltage Alarm (Volts):

10.5V

Low Battery Voltage Shutdown (Volts):

10V

AC Outlets:

1

Circuit Protection (DC Overload):

40-amp fuse (external)

*Maximum output power (continuous or peak) only available when vehicle battery is properly charged. Run vehicle engine often to maintain proper charge.

**Peak Output Power is instantaneous. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.

Typical Runtimes Before Battery Recharge

Although you can operate your Inverter with your vehicle engine off, best results are usually attained with the engine running. Since the Inverter converts electrical energy (and doesn’t produce it), the Inverter’s performance is relative to the condition of your vehicle’s electrical system (battery, alternator and wiring). If other loads (air conditioner, heater, lights, etc.) are also using power, you may get less runtime.

 

With Typical

With Typical

With Typical

 

 

Compact Vehicle (4 cylinder)

Mid-Size Vehicle (6 cylinder)

Full-Size Vehicle (8 cylinder)

 

Battery, Alternator

Battery, Alternator

Battery, Alternator

Model: PVINT375

& Wiring

& Wiring

& Wiring

 

 

 

 

1/2 Load (engine on/engine off)

continuous/1-2 hours

continuous/2-3 hours

continuous/3-6 hours

 

 

 

 

Full Load* (engine on/engine off)

continuous/30 min-1 hour

continuous/1-2 hours

continuous/2-3 hours

 

 

 

 

 

Vehicle Electrical System Limitations

NOTE: Due to the limitations of certain vehicles’ 12V DC lighter/accessory outlet electrical systems, you may not be able to continuously run a full load (375 watts) from your PVINT375. If you regularly blow fuses, it may indicate your vehicle is not adequately wired to support a PVINT375 as it is designed. In this case, consult vehicle manufacturer recommendations for rewiring from the fuse block or battery with appropriate wiring (8 - 10 gauge) and fusing (at least 40 amp).