Battery Replacement Door

Battery Replacement Door

Under normal conditions, the original batteries in your UPS will last several years. Battery replacement should only be performed by qualified service personnel. Refer to “Battery Warnings” in the Safety section on page 2. When replacing batteries, qualified service personnel should follow this procedure: 1) turn UPS OFF; 2) remove the battery door located on the front panel; 3) pull batteries partially out of the case; 4) make a detailed sketch of the batteries and the polarity, color and connection of all cables; 5) disconnect battery terminals; 6) dispose of used batteries; 7) reconnect replacement batteries exactly as original batteries were; 8) push batteries back into case and replace cover.*

* You may not receive full runtime until your replacement batteries have fully charged.

Storage & Service

Storage

Turn your UPS OFF: first, engage the ON/Standby Switch and release it to place your UPS in the “Standby” mode; then set the System Enable Switch* to “DISABLE”; finally, disconnect the UPS power cord from the wall outlet. If you plan on storing your UPS for an extended period of time, recharge the UPS batteries once every three months. Follow steps #1 and #3 in the Installation section and allow the UPS to charge from 4 to 6 hours. If you leave your UPS batteries discharged for an extended period of time, they will suffer permanent loss of capacity.

* The location of the switch varies by model. See page 3.

Service

If returning your UPS to Tripp Lite, please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit. Enclose a letter describing the symptoms of the problem. If the UPS is within the 2 year warranty period, enclose a copy of your sales receipt.

Specifications

 

SMART INT 1400 RM

SMART INT 2200 RM

Output Capacity (VA/Watts):

1400/940

2200/1750

Battery Runtime (Half Load/Full Load) Min.:

26/10

29/13

Battery Recharge Time:

2-4 hrs.

2-4 hrs.

Suggested Circuit:

15 amp

15- or 20- amp dedicated

Approvals:

UL, CE

UL, CE

 

SMART INT 2200 RM XL

SMART INT 3000 RM

Output Capacity (VA/Watts):

2200/1750

3000/2400

Battery Runtime (Half Load/Full Load) Min.:

29+/13+

23+/7+

Battery Recharge Time:

2-4 hrs.

2-4 hrs.

Suggested Circuit:

20-amp dedicated

30-amp dedicated

Approvals:

UL, CE

UL, CE

ALL MODELS:

Input Voltage/Frequency (230V/50-60 Hz); On Line Input Voltage Range (168 - 271 Volts); Voltage-Regulated Output Voltage Range (230V±9%);OnBatteryOutputVoltageRange(230V±5%);OutputWaveformLineMode(filteredsinewave);OutputWaveformBatteryMode (PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB); AC Protection Modes (H to N, H to G, N to G).

The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change.

7