Important Safety Instructions

SAVE THESE INSTRUCTIONS

This manual contains instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty.

UPS Location Warnings

Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct sunlight.

For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C).

Leave adequate space around all sides of the UPS for proper ventilation.

UPS Connection Warnings

Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the UPS.

Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s ground connection.

Do not use extension cords to connect the UPS to an AC outlet.

If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output.

Equipment Connection Warnings

Do not use Tripp Lite UPS Systems for life support appliances in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life-support device.

Battery Warnings

Your UPS does not require routine maintenance. Do not open your UPS for any reason except battery replacement. There are no user-serviceable parts inside.

Because the batteries present a risk of electrical shock and burn from high short-circuit current, observe proper precautions. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated handles, and replace the existing batteries with the same number and type of new batteries (Sealed Lead-Acid). Do not open the batteries. Do not short or bridge the battery terminals with any object. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.). Visit Tripp Lite on the Web at www.tripplite.com/support/battery/index.cfm to locate the specific replacement battery for your UPS.

The UPS batteries are recyclable. Refer to local codes for disposal requirements, or in the USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-8-228-8379) or visit www.rbrc.com for recycling information. Do not dispose of the batteries in a fire.

Unless your UPS system includes an external battery connector, do not attempt to add external batteries.

2

Quick Installation

1Using a small tool, set the Voltage Dip Switch to match your input voltage. (All models are preset to

the 120V setting.)

Note: if the Voltage Dip Switch setting does not match your input voltage (if it is set above or below the input voltage), the UPS system will naturally consider the input voltage as a constant overvoltage or undervoltage condition. The UPS system will respond accordingly by automatically adjusting the input voltage to match the Voltage Dip Switch setting. This will cause constant, unnecessary wear on the UPS system.

2Plug one end of the detachable line cord into your UPS’s AC Input Receptacle and the other end into an electrical outlet.

Plug the UPS directly into a properly grounded, 3-wire, 15-amp AC outlet that does not share a circuit with a heavy electrical load (such as an air conditioner, refrigerator, etc.).

After plugging your UPS in, check the Site Wiring Fault LED on its rear panel. If it is lit, the outlet is improperly wired; unplug the UPS and have a qualified electrician check the outlet.

Note: Once your UPS is plugged in, it will begin charging its batteries. If this is the first time you have plugged in your UPS, or if your UPS has been in storage for a prolonged period, it will need to charge its batteries for at least 6 hours before it can support connected equipment in the event of a power failure.

3Plug your equipment into your UPS.

Your UPS is designed to support computer equipment only. You will overload your UPS if you connect devices with high power demands such as household appliances or laser printers to your UPS’s outlets.

4Turn your UPS ON:

Press the “ON/TEST” Switch

Hold it for several seconds until you hear a beep

Release it

Your UPS will begin providing power to its outlets.

3

 

SI

 

W

 

FA

 

120V

 

110V

 

100V

 

127V

1

SMART1050SLT shown

 

INPUT

2

SMART1050SLT shown

 

ACCESSORY

 

INPUT

3

SMART1050SLT shown

SMART1050SLT shown

ON/TEST

OFF

TRIMMING

4

Page 3
Image 3
Tripp Lite 1500SLT, Smart1050 Important Safety Instructions, Plug your equipment into your UPS, Turn your UPS on