Important Safety Warnings

SAVE THESE INSTRUCTIONS. This manual contains important instructions and warnings that should be followed during the installation and maintenance of this UPS System.

UPS Location Warnings

The UPS is extremely heavy. Use caution when lifting and installing.

Install your UPS indoors, away from excess moisture or heat, direct sunlight, dust and conductive contaminants.

Install your UPS in a structurally sound area.

Only operate your UPS at indoor temperatures between 32° F and 104° F (between 0° C and 40° C). For best results, keep indoor temperatures between 62° F and 84° F (between 17° C and 29° C).

Leave adequate space around all sides of the UPS for proper ventilation. Do not obstruct its ventilation fans or openings.

Do not install the UPS near magnetic storage media, as this may result in data corruption.

Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the unit's internal cooling, eventually causing product damage not covered under warranty.

UPS Connection Warnings

The power supply for this unit must be split-phase rated in accordance with the equipment nameplate. It also must be suitably grounded.

Connect your UPS system only to a four-wire input power connection (L1, L2, N, G). This UPS requires an input neutral connection.

Connect your UPS to a properly grounded AC power outlet. Do not modify the UPS's plug in a way that would eliminate the UPS's connection to ground. (Note: Model SU8000RT4U has a hardwire input instead of an input cord/plug.)

Do not use adapters that eliminate the UPS's connection to ground.

Do not plug your UPS into itself; this will damage the UPS and void your warranty.

If you are connecting your UPS to a motor-powered AC generator, the generator must provide filtered, frequency-regulated computer-grade output. Connecting your UPS to a generator will void its Ultimate Lifetime Insurance.

Equipment Connection Warnings

Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide

The UPS contains an internal DC energy source (battery). The output terminals may be live even when the UPS is not connected to an AC power source.

Do not connect surge suppressors or extension cords to the output of your UPS. This might overload the UPS and will void the surge suppressor and UPS warranties.

Maintenance Warnings

• Your UPS does not require routine maintenance. Do not open the UPS for any reason. There are no user-serviceable parts inside.

Battery Warnings

The internal batteries in your UPS are recyclable. Refer to local codes for disposal requirements, or if in the USA call 1-800-SAV-LEAD (1-800-728-5323) for complete recycling information. CAUTION: Do not dispose of the batteries in a fire, as this could cause the battery to explode.

Because the batteries present a risk of electrical shock and burn from high short-circuit current, batteries should be changed only by trained service personnel observing proper precautions. Remove watches, rings and other metal objects. Use tools with insulated handles. Wear rubber gloves and boots. Do not lay tools or metal parts on top of the batteries. Do not short or bridge the battery terminals with any object. Disconnect the charging source prior to connecting or disconnecting battery terminals. Determine if the batteries are inadvertently grounded. If inadvertently grounded, remove the source of the ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance.

Do not open or mutilate the batteries. Released electrolyte is harmful to the skin and eyes, and may be toxic.

Fuses should be replaced only by factory-authorized personnel. Blown fuses should be replaced only with fuses of the same number and type.

Service and repair should be done only by trained personnel. During any service work to the UPS, it should be turned off. Note that potentially lethal voltages exist within this unit as long as the battery supply is connected.

Do not connect or disconnect external battery pack(s) while the UPS is operating from the battery.

During hot-swap battery replacement, the UPS will not provide backup power in the event of a blackout or other power interruptions.

Do not operate UPS without batteries.

When adding external battery packs to models with external battery pack connectors, connect only Tripp Lite-recommended battery packs of the correct voltage and type.

2

Page 2
Image 2
Tripp Lite SU5000RT4U, SU8000RT4U, SU6000RT4U owner manual Important Safety Warnings

SU5000RT4U, SU6000RT4U, SU8000RT4U specifications

Tripp Lite is a renowned name in the realm of power protection solutions, and their line of uninterruptible power supplies (UPS) stands out for providing superior performance and advanced features. The Tripp Lite SU6000RT4U, SU5000RT4U, and SU8000RT4U are all remarkable options designed for various applications, ensuring consistent power delivery and robust protection against electrical disturbances.

The SU6000RT4U is a 6000VA/5400W UPS system that offers exceptional reliability to safeguard your critical equipment. It features a dual-conversion online design, which guarantees a steady output voltage regardless of fluctuations in input power. The hot-swappable batteries allow for uninterrupted power, ensuring that maintenance can occur without downtime. The graphical LCD display provides real-time information about UPS status, input/output voltage, and battery condition, enabling users to monitor performance effortlessly.

Next in line, the SU5000RT4U offers a 5000VA/4500W capacity and similar technological advancements. This model is engineered to support high-sensitive equipment, making it perfect for data centers, networking devices, and other critical applications. It includes advanced surge protection, ensuring that any spikes in electricity do not cause damage to connected devices. Like the SU6000RT4U, it also employs a dual-conversion design for superior power quality.

The SU8000RT4U is an impressive 8000VA/7200W UPS that caters to demanding applications. In addition to the features found in the smaller models, it boasts an extensive runtime, allowing it to sustain operations during prolonged power outages. This model also supports advanced management options, such as SNMP networking capabilities, which grants users the ability to monitor and manage the UPS remotely via any networked device. The battery management technology extends battery life and enhances performance, making it a standout choice for high-efficiency environments.

All three Tripp Lite UPS units are designed with foolproof safety measures, including automatic voltage regulation, isolating transformers, and thermal protection to promote longevity and reliability. Built with a rugged metal housing, they ensure durability in a variety of conditions. Compact and rack-mountable, these UPS systems fit seamlessly into data racks or server environments. With their robust features, the SU6000RT4U, SU5000RT4U, and SU8000RT4U ensure that your valuable equipment is always protected from the unpredictability of power supply issues.