Îñíîâíûå îïåðàöèè

Âêëþ÷àòåëè íà ïåðåäíåé ïàíåëè

Âêëþ÷àòåëü "ON/TEST": Ýòîò âêëþ÷àòåëü çàäåéñòâóåò ÷åòûðå îòäåëüíûå ôóíêöèè ÈÁÏ.

Âêëþ÷åíèå ÈÁÏ

×òîáû âêëþ÷èòü ÈÁÏ, íàæèìàéòå ýòîò âêëþ÷àòåëü â òå÷åíèå íåñêîëüêèõ ñåêóíä, ïîêà íå ñðàáîòàåò çâóêîâîé ñèãíàë, çàòåì îòïóñòèòå åãî. Çàãîðèòñÿ ñâåòîäèîä "ON LINE".

Ñàìîäèàãíîñòèêà ÈÁÏ

Âî âðåìÿ íîðìàëüíîé ðàáîòû ñîâìåñòíî ñ ïîäêëþ÷åííûì îáîðóäîâàíèåì íàæèìàéòå ýòîò âêëþ÷àòåëü, ïîêà íå óñëûøèòå çâóêîâîé ñèãíàë. Íà÷èíàåòñÿ 10-ñåêóíäíàÿ ñàìîäèàãíîñòèêà áàòàðåè. ÈÁÏ ïåðåéäåò íà ðåæèì ïèòàíèÿ îò áàòàðåè (ïðè ýòîì çàãîðÿòñÿ ñâåòîäèîäû "ON BATT" è "BATT ACTIVE METER") íà 10 ñåêóíä.

Îòêëþ÷åíèå ñèãíàëà òðåâîãè

×òîáû îòêëþ÷èòü ñèãíàë ðåæèìà ïèòàíèÿ îò áàòàðåè ÈÁÏ, íàæèìàéòå ýòîò âêëþ÷àòåëü, ïîêà íå óñëûøèòå çâóêîâîé ñèãíàë.

Õîëîäíûé ïóñê ÈÁÏ

×òîáû èñïîëüçîâàòü ÈÁÏ â êà÷åñòâå àâòîíîìíîãî èñòî÷íèêà ïèòàíèÿ ïðè îòñóòñòâèè ýëåêòðîïèòàíèÿ ïåðåìåííûì òîêîì (íàïðèìåð, âî âðåìÿ àâàðèéíîãî ïåðåðûâà â ýíåðãîñíàáæåíèè), íàæèìàéòå ýòîò âêëþ÷àòåëü, ïîêà íå óñëûøèòå çâóêîâîé ñèãíàë. Ïîñëå ýòîãî ÈÁÏ íà÷íåò ïîäàâàòü íà ðîçåòêè ïèòàíèå îò áàòàðåè.*

*Çàãîðèòñÿ èíäèêàòîð "ON BATT", ò.ê. ÈÁÏ áóäåò ðàáîòàòü îò áàòàðåè.

Âûêëþ÷àòåëü "OFF": Ýòîò âûêëþ÷àòåëü ïðåêðàùàåò ïîäà÷ó ïèòàíèÿ íà ðîçåòêè ÈÁÏ. íàæèìàéòå ýòîò âêëþ÷àòåëü, ïîêà íå óñëûøèòå çâóêîâîé ñèãíàë, çàòåì îòïóñòèòå åãî. ÈÁÏ ïðîäîëæèò çàðÿäêó áàòàðåè, è âåíòèëÿòîð ïðîäîëæèò îõëàæäåíèå âíóòðåííèõ äåòàëåé äàæå ïîñëå òîãî, êàê âû îòêëþ÷èòå ïîäà÷ó ïèòàíèÿ íà ðîçåòêè. ×òîáû ïîëíîñòüþ îòêëþ÷èòü ÈÁÏ, â òîì ÷èñëå è çàðÿäíîå óñòðîéñòâî, îòñîåäèíèòå êàáåëü ïèòàíèÿ ÈÁÏ ïîñëå íàæàòèÿ âûêëþ÷àòåëÿ "OFF".

Êîíòðîëüíûå ëàìïû íà ïåðåäíåé ïàíåëè

Ñâåòîäèîä "ON LINE": Ýòîò çåëåíûé èíäèêàòîð ãîðèò ïîñòîÿííûì ñâåòîì, ïîêàçûâàÿ, ÷òî ÈÁÏ íîðìàëüíî ðàáîòàåò ñîâìåñòíî ñ ïîäêëþ÷åííûì îáîðóäîâàíèåì (ôèëüòðóåò è ðåñèíòåçèðóåò ïîñòóïàþùèé èç ñåòè ïåðåìåííûé òîê, ïîäàâàÿ íà âûõîä ïèòàíèå ñ ÷èñòîé ñèíóñîèäîé). Êîãäà çàãîðàåòñÿ ýòîò èíäèêàòîð, âû ìîæåòå îòñëåæèâàòü óðîâåíü íàãðóçêè íà ÈÁÏ ïðè ïîìîùè ñâåòîäèîäîâ

"LOAD ACTIVE METER".

Ñâåòîäèîä "LINE": Ýòîò çåëåíûé èíäèêàòîð ãîðèò ïîñòîÿííî, ïîêàçûâàÿ, ÷òî ïîñòóïàþùèé íà ðîçåòêó ïåðåìåííûé òîê îò ýíåðãîñåòè ñîîòâåòñòâóåò íîìèíàëó. Îí íà÷íåò ìèãàòü, åñëè íàïðÿæåíèå ñåòåâîé òîê íå ñîîòâåòñòâóåò íîìèíàëó (ëèáî ñëèøêîì âûñîêîå, ëèáî ñëèøêîì íèçêîå). Ñ âàøåé ñòîðîíû íåò íåîáõîäèìîñòè ïðåäïðèíèìàòü êàêèå-ëèáî äåéñòâèÿ â ñâÿçè ñ ìèãàþùåé èíäèêàöèåé ñâåòîäèîäà - ÈÁÏ íåïðåðûâíî àâòîìàòè÷åñêè ôèëüòðóåò ïåðåìåííûé òîê îò ýíåðãîñåòè, ïîäàâàÿ íà âàøå îáîðóäîâàíèå ïåðåìåííûé òîê ñ ÷èñòîé ñèíóñîèäîé íåçàâèñèìî îò ñíèæåíèÿ èëè ïîâûøåíèÿ íàïðÿæåíèÿ. Åñëè ýòîò èíäèêàòîð ïîãàñ, òî ýòî îçíà÷àåò , ÷òî â ëèíèè ñåòåâîãî ïèòàíèÿ òîêà íåò (ïåðåðûâ â ýíåðãîñíàáæåíèè) ëèáî íàïðÿæåíèå òîêà ñëèøêîì âûñîêîå; â ýòîì ñëó÷àå ÈÁÏ ïîäàåò íà ïîäêëþ÷åííîå îáîðóäîâàíèå ýëåêòðîïèòàíèå îò áàòàðåè.

51

Page 51
Image 51
Tripp Lite SUINT1500RTXL2U, SU1500RTXL2UHV owner manual Îñíîâíûå îïåðàöèè, Load Active Meter

SU1500RTXL2UHV, SUINT1500RTXL2U, SU1500RTXL2U specifications

The Tripp Lite SU1500RTXL2U is a versatile and reliable uninterruptible power supply (UPS) designed to provide protection for critical electronic equipment in various environments. With a power capacity of 1500 VA and a power output of 1000 Watts, this UPS is ideal for small servers, network equipment, and other sensitive devices that require consistent and uninterrupted power.

One of the standout features of the SU1500RTXL2U is its ability to offer extended runtime configurations. The unit includes a built-in battery, but it is also compatible with additional external battery packs that can be connected to prolong the UPS's runtime during power outages. This capability is particularly useful for businesses that cannot afford downtime and require extended periods of operation during an electrical failure.

Equipped with line-interactive technology, the SU1500RTXL2U provides reliable voltage regulation. It automatically adjusts voltage levels to maintain optimal power supply conditions, ensuring that connected devices receive a stable output. This feature significantly reduces the risk of damage from power surges, sags, and other irregularities.

Additionally, this Tripp Lite model features eight NEMA 5-15R outlets, allowing multiple devices to be connected simultaneously. It provides a combination of battery backup and surge protection, safeguarding equipment against potential damage from power spikes or outages. The UPS also includes an LCD screen that offers real-time information on battery status, load capacity, and input/output voltages, enabling users to monitor performance easily.

The SU1500RTXL2U is designed with user-friendliness in mind. Its compact 2U rack-mountable form factor facilitates easy installation in standard network racks or server rooms. The built-in smart management software ensures seamless integration with most operating systems, allowing users to configure settings and monitor the UPS through their computers.

Furthermore, the SU1500RTXL2U is equipped with an automatic voltage regulation (AVR) feature, enabling it to maintain consistent output voltage levels without draining the battery. This not only enhances operational efficiency but also extends the lifespan of the unit's batteries.

In conclusion, the Tripp Lite SU1500RTXL2U is an exceptional UPS solution equipped with essential features that ensure the reliability and stability of power supply for sensitive equipment. Its extended runtime options, line-interactive technology, and user-friendly design make it an indispensable asset for any organization relying on uninterrupted power.