Important Safety Instructions

Quick Installation

SAVE THESE INSTRUCTIONS

This manual contains instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems.

UPS Location Warnings

Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct sunlight.

For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C).

Leave adequate space around all sides of the UPS for proper ventilation.

Do not install the UPS near magnetic storage media, as this may result in data corruption.

UPS Connection Warnings

Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the UPS.

Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s ground connection.

Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be voided if anything is used to connect your UPS to an outlet.

If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output.

1Plug the UPS into an outlet

on a dedicated circuit.*

NOTE! after you plug the UPS into a live AC outlet, the UPS will automatically charge its batteries,** but will not supply power to its outlets until it is turned ON (see Step 3 below).

*See Specifications for circuit amperage requirements. Select models include an additional plug which can be switched by a qualified electrician. See Specifications for details. ** The BATTERY CHARGE LED will be the only LED illuminated.

2Plug your equipment into the UPS.*

*Your UPS is designed to only support computer equipment. You will overload the UPS if the total VA ratings for all the equipment you connect exceeds the UPS’s Output Capacity (see Specifications). To find your equipment’s VA ratings, look on their nameplates. If the equipment is listed in amps, multiply the number of amps by 120 to determine VA. (Example: 1 amp × 120 = 120 VA). If you are unsure if you have overloaded the UPS’s outlets, see “OUTPUT LOAD LEVEL” LED description.

1 SMART2200VSXL shown

2 SMART2200VSXL shown

Equipment Connection Warnings

Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life-support device.

Do not connect surge suppressors or extension cords to the output of your UPS. This might overload the UPS and will void the surge suppressor and UPS warranties.

Battery Warnings

Your UPS does not require routine maintenance. Do not open your UPS for any reason except battery replacement. There are no user-serviceable parts inside.

Because the batteries present a risk of electrical shock and burn from high short-circuit current, observe proper precautions. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated handles, and replace the existing batteries with the same number and type of new batteries (Sealed Lead-Acid). Do not open the batteries. Do not short or bridge the battery terminals with any object. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.). Visit Tripp Lite on the Web at www.tripplite.com/support/battery/index.cfm to locate the specific replacement battery for your UPS.

The UPS batteries are recyclable. Refer to local codes for disposal requirements, or in the USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-8-228-8379) or visit www.rbrc.com for recycling information. Do not dispose of the batteries in a fire.

If your UPS model is equipped with an external battery connector, only connect Tripp Lite battery packs of the appropriate type and correct voltage. Do not connect or disconnect external batteries while the UPS is operating from battery.

3

Turn the UPS ON.

Press and hold the “POWER” button for one second. The alarm will beep once briefly after one second has passed. Release the button.

3

2

3

Page 2
Image 2
Tripp Lite VS owner manual Important Safety Instructions Quick Installation

VS specifications

Tripp Lite is a well-known brand in the realm of power protection and connectivity solutions, particularly recognized for its innovative VS (Virtual Server) series. The Tripp Lite VS series is engineered to provide exceptional performance, reliability, and efficiency, catering to a variety of applications ranging from data centers to office environments.

One of the main features of the Tripp Lite VS series is its advanced power management capabilities. These systems often incorporate smart technologies that optimize power distribution, monitor energy usage, and ensure stable power delivery. Users can benefit from real-time data, allowing for proactive management of electricity consumption and potentially leading to significant cost savings.

Another standout characteristic of the VS series is its robust surge protection. This feature protects connected devices from voltage spikes and electrical surges, which can cause damage and data loss. Tripp Lite incorporates advanced surge suppression technologies that safeguard sensitive electronics, making it an ideal choice for environments with substantial electronic equipment.

The design and build quality of the Tripp Lite VS series are also noteworthy. Units are typically constructed with durable materials, ensuring longevity even in challenging environments. They often feature fan-less designs for quiet operation and may include various mounting options, including rack mounts and wall mounts, providing flexibility in installation.

Connectivity is another strong suit of the Tripp Lite VS series. Devices are usually equipped with multiple outlets and ports, enabling seamless connection to various peripherals such as servers, routers, and even administrative hardware. This multi-port capability is vital for expanding network infrastructure or connecting multiple devices in a single workstation.

Ease of use is prioritized in the Tripp Lite VS series, with user-friendly interfaces that simplify monitoring and management tasks. Many models boast LCD displays that provide essential information like power load, battery status, and runtime estimates, aiding users in making informed decisions about power usage.

Incorporating state-of-the-art technologies like automatic voltage regulation (AVR) and battery backup features ensures that the Tripp Lite VS series delivers reliable performance in case of power outages. This is an essential characteristic for businesses that rely on uptime, making it a favored choice among IT professionals and network administrators.

Overall, the Tripp Lite VS series stands out due to its combination of advanced features, high-quality construction, and user-friendly design, making it an excellent option for anyone seeking reliable power management and protection solutions.