Troy-Bilt 4510 warranty Troubleshooting, Problem, Cause, Remedy

Models: 4510

1 28
Download 28 pages 54.39 Kb
Page 24
Image 24
Troubleshooting

Troubleshooting

8

Problem

Cause

Remedy

Engine fails to start

1.

Choke control not in ON position.

1.

Move choke control to ON position.

 

2.

Spark plug wire disconnected.

2.

Connect wire to spark plug.

 

3.

Fuel tank empty or stale fuel.

3.

Fill tank with clean, fresh gasoline.

 

4.

Engine not primed.

4.

Prime engine as instructed in the Operation

 

 

 

 

section.

 

5.

Faulty spark plug.

5.

Clean, adjust gap, or replace spark plug.

 

6.

Safety key not inserted .

6.

Insert key fully into the switch.

 

 

 

 

 

Engine runs erratic

1.

Engine running on CHOKE.

1.

Move choke control to OFF position.

 

2.

Stale fuel.

2.

Fill tank with clean, fresh gasoline.

 

3.

Water or dirt in fuel system.

3.

Drain fuel tank. Refill with fresh fuel.

 

4.

Carburetor out of adjustment.

4.

Contact a Briggs & Stratton Engine Service

 

 

 

 

Center.

 

 

 

 

 

Engine overheats

1.

Carburetor not adjusted properly.

1.

Contact a Briggs & Stratton Engine Service

 

 

 

 

Center.

 

 

 

 

 

Excessive vibration

1.

Loose parts or damaged auger.

1.

Stop engine immediately and disconnect

 

 

 

 

spark plug wire. Tighten all bolts and nuts. If

 

 

 

 

vibration continues, have unit serviced by an

 

 

 

 

authorized Service Center.

 

 

 

 

 

Loss of power

1.

Spark plug wire loose.

1.

Connect spark plug wire.

 

2.

Gas cap vent hole plugged.

2.

Remove ice and snow from gas cap. Be

 

 

 

 

certain vent hole is clear.

 

 

 

 

 

Unit fails to propel itself

1.

Drive control cable in need of adjustment.

1.

Adjust drive control cable. Refer to

 

 

 

 

Maintenance & Adjustments section.

 

2.

Drive belt loose or damaged.

2.

Replace drive belt. Refer to Service section

 

3.

Friction wheel worn.

3.

Replace friction wheel.

 

 

 

 

 

Unit fails to discharge snow

1.

Chute assembly clogged.

1.

Stop engine immediately and disconnect

 

 

 

 

spark plug wire. Clean chute assembly and

 

 

 

 

inside of auger housing with clean-out tool

 

 

 

 

or a stick.

 

2.

Foreign object lodged in auger.

2.

Stop engine immediately and disconnect

 

 

 

 

spark plug wire. Remove object from auger

 

 

 

 

with clean-out tool or a stick.

 

3.

Auger control cable in need of adjustment.

3.

Adjust auger control cable. Refer to Assembly

 

 

 

 

& Set-Up section.

 

4.

Auger belt loose or damaged.

4.

Replace auger belt refer to Service section.

 

5.

Shear pin(s) sheared.

5.

Replace shear pin(s).

 

 

 

 

 

24

Page 24
Image 24
Troy-Bilt 4510 warranty Troubleshooting, Problem, Cause, Remedy