Calibration Procedures

455 Calibration

Enter Calibration Mode by holding the Up and Down keys while inserting the safety key In message center window displayed: Press Start to Calibrate

NOTE: In Calibration mode, it is possible to check if the speed sensor is reading all the front roller

magnets: the Met light will light when a magnet is in front of the sensor. Speed must be less than 1 mph.

Press Start/Reset to begin calibration

Treadmill will elevate and speed up/slow down. Wait for belt to stop.

Message center window will display: Successful, or will indicate error area.

Remove and re-insert safety key. Check operation of treadmill.

Page 14

Support Services 800-883-8783

Mon-Fri 8:30am-5:00pm Central Time Zone

Fax: 636-272-7148

 

 

 

Page 16
Image 16
True Fitness 455 Pediatric manual Calibration Procedures