STARTUP

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

STARTUP

Step 6

A.The compressor is ready to operate. Plug in the unit.

PLEASE REVIEW THE FOLLOWING CAUTIONS WHEN THE OPTIONAL HEATED PAN IS USED.

CAUTION:

This unit has two power supply cords. Unplug both cords before moving or servicing this appliance.

CAUTION:

This unit has two power supply cords. Connect each plug to a receptacle that is connected to an individual branch circuit.

CAUTION:

This unit has more than one disconnect switch (plug).

B.Temperature control set at No. 4 position gives refrigerators an approximate temperature of 33°F to 38˚F (.5˚C to 3.3˚C). Allow unit to function several hours, completely cooling cabinet before changing the control setting.

C.Excessive tampering with the control could lead to service difficulties. Should it ever become necessary to replace temperature control, be sure it is ordered from your True dealer or recommended service agent.

D.Good air flow in your True unit is critical. Be careful to load product so that it neither presses against the back wall, nor comes within four inches of the evaporator housing. Refrigerated air off the coil must circulate down the front of the shelves.

NOTE

If the unit is disconnected or shut off, wait five minutes before starting again.

RECOMMENDATION

Before loading product we recommend you run your True unit empty for two to three days. This allows you to be sure electrical wiring and installation are correct and no shipping damage has occurred. Remember, our factory warranty does not cover product loss!

REPLACEMENT PARTS

TRUE maintains a record of the cabinet serial number for your unit. If at any time during the life of your display case, a part is needed, you may obtain this part by furnishing the model number and serial number to the company from whom you purchased the cabinet. Call Toll-Free: (800)-424-TRUE (Direct to Parts Department). (800)-325- 6152 (U.S.A. & Canada only) or call: (636)-240-2400.

Serial Number

LIGHT SWITCH LOCATION:

The light switch is located behind the interior light on the ceiling. Depending on the model the switch will be either on the left or right side of the ceiling.

REMOTE UNITS (This section applies to remotes only!)

Remote cabinets must be ordered as remote. We do not recommend converting a standard self contained to remote system.

All remote cabinets must be hard wired.

Remote cabinets are not available with castors.

All remote cabinets come standard using 404A refrigerant.

All remote units come standard with expansion valve, liquid line solenoid, heated condensate pan, and defrost timer when applicable.

Contact True Technical Service for BTU require- ments.

No wiring necessary between cabinet and con- densing unit.

All remote condensing units purchased from True are 208/230 volts single phase.

If you have any questions regarding this section, please call True at 1 (800) 325-6152.