True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

DEFROST TIME CLOCK OPERATION

Instructions for TAC-48, TAC-48GS, and TAC-72RC models.

RECOMMENDED DEFROST SETTINGS:

True Manufacturing has factory set your defrost time clock to a recommended time and duration defrost scenario. Your True equipment has been designed for three defrost periods (6:00 a.m., 2:00 p.m. and 10:00 p.m.). If you decide to deviate from these defrost time settings please follow the

procedures for adjustment below.

NOTE:

Defrost timer will need to

be set at current time of day

before plugging unit into power supply. The defrost times have been set from the factory. If you want to change defrost times please read through the defrost timer

instructions.

REQUIRED TOOLS:

Phillips Screwdriver

1/4” Nut Driver or Socket

TAC Defrost Timer Location: Defrost timer is located in a ballast box behind the front louvered grill on the left side of the unit. Four corner screws on the front louvered grill will need to be removed. The ballast box has two 1/4” hex head screws that need to be removed to gain access to the defrost control.

Setting the timer:

(UNPLUG UNIT FROM

POWER SUPPLY!)

Adjusting The Defrost Timer:

(time initiated, time terminated)

Your True equipment contains a defrost system that is time initiated and time terminated. While True requires a minimum 3 defrost periods not to exceed 30 minutes the procedure on this page should be followed to customize your specific needs.

Notice:

If timer is not set for a minimum of 3

defrost per day for 30 minutes each, the coil may develop excessive frost. This may lead to system failure and product loss, which is not covered under warranty.

The following procedure may be followed to customize your needs.

High usage, high temperature, and high humidity may require 4 defrost settings per day.

WARNING:

Always follow the

manufacturer’s recommended settings when programming the amount and duration of the defrost cycles.

STEP 1

The white tabs located on the outmost area of the time clock have been factory set for (6:00 a.m., 2:00 p.m., and 10:00 p.m.).

Each tab represents 15 minutes of defrost time. Notice that at each defrost time two white tabs are set for 15 minutes each for a total of 30 minutes of defrost.

STEP 2

In order to program the time to begin the defrost cycle, flip the white tabs out to set the defrost time. To eliminate a defrost time flip the white tabs back toward the center of the Defrost Timer.

STEP 3

True recommends a 30 minute defrost cycle three times per day.

Defrost Timer Box Image 1

DO NOT SET THE TIME BY

ROTATING THE “OUTER” DIAL.

Turn the minute hand clockwise until the time of day on the outer dial is aligned with the triangle marker on the inner dial (two o’clock position).

Outer most dial. White tabs represent 15 minutes of defrost time.

Time of day.

Inner most dial.

 

Defrost Timer Image 2

 

12

www.truemfg.com

12

Page 14
Image 14
True Manufacturing Company TAC-30 Defrost Time Clock Operation, Instructions for TAC-48, TAC-48GS, and TAC-72RC models

TAC-30, TAC-36, 72RC specifications

True Manufacturing Company, a leader in refrigeration and foodservice equipment, has gained a stellar reputation for its high-quality products, including models such as the 72RC, TAC-36, and TAC-30. These models showcase innovative design, robust construction, and energy-efficient technologies, making them industry favorites for commercial kitchens, restaurants, and grocery stores.

The True 72RC is a triple-door reach-in refrigerator that exemplifies reliability and performance. With a spacious interior, it offers a capacity of 72 cubic feet, making it perfect for businesses that require ample storage for perishable items. Its exterior is constructed from high-grade stainless steel, ensuring durability and easy maintenance. The self-closing doors feature a positive seal to help maintain internal temperatures while contributing to energy savings. Additionally, the unit's refrigeration system operates silently, enhancing the working environment for staff.

The TAC-36 and TAC-30 models are part of True's undercounter series, designed for efficiency and versatility. The TAC-36 features a spacious countertop and provides convenient access to frequently used ingredients, making it ideal for busy kitchens. With its 36-inch width, it fits seamlessly under standard work tables. The unit boasts a bottom-mounted refrigeration system, providing easy access for maintenance while also ensuring a consistent temperature for stored items.

Similarly, the TAC-30 model is compact yet functional, making it suitable for establishments with limited space. At just 30 inches wide, it still maintains a significant internal capacity for storage, catering to the needs of smaller operations. Both TAC models are equipped with True's signature R290 refrigerant, which is known for its low environmental impact, enhancing their eco-friendly profile.

All models incorporate True's advanced refrigeration technology, which features a factory-installed capillary tube system that ensures optimal efficiency and temperature control. Additionally, the digital temperature display allows for easy monitoring and adjustments, ensuring that all products are stored at safe temperatures.

In summary, True Manufacturing Company's 72RC, TAC-36, and TAC-30 models represent cutting-edge solutions for commercial refrigeration needs. With a focus on durability, energy efficiency, and user-friendly design, these products are essential assets for any foodservice operation seeking reliability and performance.