INSTALLATION / OPERATION INSTRUCTIONS

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

INSTALLATION / OPERATION INSTRUCTIONS

OWNERSHIP

To insure that your unit works properly from the first day, it must be installed properly. We highly recommend a trained refrigeration mechanic and electrician install your True equipment. The cost of a professional installation is money well spent.

REQUIRED TOOLS

Before you start to install your True unit, carefully inspect it for freight damage. If damage is discovered, immediately file a claim with the delivery freight carrier.

True is not responsible for damage incurred during shipment.

Adjustable Wrench

Phillips Head Screwdriver

Level

UNCRATING

Step 1

The following procedure is recommended for uncrating the unit:

A. Remove the outer packaging, (cardboard and

 

bubbles or styrofoam corners and clear plastic).

 

 

 

 

 

 

 

Inspect for concealed damage.Again,

 

 

 

 

 

 

 

immediately file a claim with the freight carrier

 

 

 

 

 

 

 

 

1

 

 

 

 

if there is damage.

 

 

 

 

B. Move your unit as close to the final location as

 

 

 

 

 

 

 

possible before removing the wooden skid.

 

 

 

 

 

 

C. Remove door bracket on swinging glass door

 

 

 

 

 

 

 

models (see image 1-2).

 

 

 

 

 

 

Note: Keys for coolers with door locks are located

 

 

 

 

 

 

 

in warranty packets.

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

REMOTE UNITS (This section applies to

 

 

 

 

 

 

remotes only!)

• Contact True Technical Service for BTU

 

• Remote cabinets must be ordered as remote.

requirements.

 

 

We do not recommend converting for a standard

• No wiring necessary between cabinet and

 

 

self contained to remote system.

condensing unit.

 

• All remote cabinets must be hard wired.

• All remote condensing units purchased from

 

No castors available.

True are 208/230 volts single phase.

 

• All remote cabinets come standard using 404A

If you have any questions regarding this

 

 

refrigerant.

section, please call True at 1-(800)-325-6152.

 

• All remote units come standard with expansion

 

 

 

 

 

 

 

valve, liquid line solenoid, heated condensate

 

 

 

 

 

 

 

pan, and defrost timer when applicable.

 

 

 

 

 

 

5