True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

LOCATING

Warning

For proper performance of refrigerated cabinet an ambient temperature no greater than 75°F (24°C) with a relative humidity of 55% is required.

TOOLS REQUIRED:

Phillips screw driver

3/8” (9.5 mm) socket or 3/8” (9.5 mm) wrench

Step 2

A.Use a Phillips screw diver and remove four screws from the L-bracket connected the unit to the wood skid (image 1). Then use a 3/8” (9.5 mm) socket or wrench and remove the L-brack- et from the unit (image 2).

To avoid damage to glass DO NOT lay cabinet on its side or back when removing skid, installing leg

levelers, cleaning, etc.

B.Lift up from the base and walk unit off the skid and set in final location.

C.Unblock doors, (free plastic wedges, blue foam

and tape. Remove fiberglass tape securing glass.

Remove components: (shelves, brackets, etc.) from inside cabinet.

1

Removing bracket from skid.

2

Removing bracket from cabinet.

LEVELING

Step 3

A.Set unit in its final location. Be sure there is adequate ventilation in your room. Under extreme heat conditions, (100˚F +, 38˚C+), you may want to

install an exhaust fan.

Warning

Warranty is void if ventilation is insufficient.

A.Proper leveling of your True unit is critical to operating success (for non-mobile models). Effective condensate removal and door operation will be effected by leveling.

Warning

Display case must be leveled accurately to ensure front glass door seals properly.

B.The unit should be leveled front to back and side to side with a level. Place the level in the interior floor of the unit and check all four sides.

C.If the cabinet is not level adjust leg levelers by first relieving weight to leveler and adjusting by either hand or wrench. Repeat with all leg level- ers until cabinet is level in all directions.

D.Ensure that the drain hose or hoses are posi- tioned in the pan.

E.Models with power cord: Free plug and cord from inside the lower rear of the cooler (do not plug in).

F.Models with power cord: The unit should be placed close enough to the electrical supply so that extension cords are never used.

Warning

Compressor warranties are void if the unit is more than 9 ft. (3 m) from plug-in connection or an exten- sion cord is used to connect unit to a power supply.

5

www.truemfg.com

5

Page 7
Image 7
True Manufacturing Company TCGDZ-50 Locating, Leveling, Tools Required, Warranty is void if ventilation is insufficient