True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

CONDUCTORS AND CIRCUITS

Wire Gauge for 2% Voltage Drop in Supply Circuits.

115 Volt

 

 

Distance In Feet To Center of Load

 

 

 

Amps

20

30

40

50

60

70

80

90

100

120

140

160

2

14

14

14

14

14

14

14

14

14

14

14

14

3

14

14

14

14

14

14

14

14

14

14

14

12

4

14

14

14

14

14

14

14

14

14

12

12

12

5

14

14

14

14

14

14

14

12

12

12

10

10

6

14

14

14

14

14

14

12

12

12

10

10

10

7

14

14

14

14

14

12

12

12

10

10

10

8

8

14

14

14

14

12

12

12

10

10

10

8

8

9

14

14

14

12

12

12

10

10

10

8

8

8

10

14

14

14

12

12

10

10

10

10

8

8

8

12

14

14

12

12

10

10

10

8

8

8

8

6

14

14

14

12

10

10

10

8

8

8

6

6

6

16

14

12

12

10

10

8

8

8

8

6

6

6

18

14

12

10

10

8

8

8

8

8

8

8

5

20

14

12

10

10

8

8

8

6

6

6

5

5

25

12

10

10

8

8

6

6

6

6

5

4

4

30

12

10

8

8

6

6

6

6

5

4

4

3

35

10

10

8

6

6

6

5

5

4

4

3

2

40

10

8

8

6

6

5

5

4

4

3

2

2

45

10

8

6

6

6

5

4

4

3

3

2

1

50

10

8

6

6

5

4

4

3

3

2

1

1

Wire Gauge for 2% Voltage Drop in Supply Circuits.

230 Volt

 

 

Distance In Feet To Center of Load

 

 

 

Amps

20

30

40

50

60

70

80

90

100

120

140

160

5

14

14

14

14

14

14

14

14

14

14

14

14

6

14

14

14

14

14

14

14

14

14

14

14

12

7

14

14

14

14

14

14

14

14

14

14

12

12

8

14

14

14

14

14

14

14

14

14

12

12

12

9

14

14

14

14

14

14

14

14

12

12

12

10

10

14

14

14

14

14

14

14

12

12

12

10

10

12

14

14

14

14

14

14

12

12

12

10

10

10

14

14

14

14

14

14

12

12

12

10

10

10

8

16

14

14

14

14

12

12

12

10

10

10

8

8

18

14

14

14

12

12

12

10

10

10

8

8

8

20

14

14

14

12

10

10

10

10

10

8

8

8

25

14

14

12

12

10

10

10

10

8

8

6

6

30

14

12

12

10

10

10

8

8

8

6

6

6

35

14

12

10

10

10

8

8

8

8

6

6

5

40

14

12

10

10

8

8

8

6

6

6

5

5

50

12

10

10

8

6

6

6

6

6

5

4

4

60

12

10

8

6

6

6

6

6

5

4

4

3

70

10

10

8

6

6

6

5

5

4

4

2

2

80

10

8

8

6

6

5

5

4

4

3

2

2

90

10

8

6

6

5

5

4

4

3

3

1

1

100

10

8

6

6

5

4

4

3

3

2

1

1

7

............ www.truemfg.com

7

Page 9
Image 9
True Manufacturing Company TCGDZ-50 installation manual Conductors and Circuits