True Manufacturing Company TCGDZ-50 Temperature Control Adjustment For High Altitude Only, Terms

Models: TCGDZ-50

1 21
Download 21 pages 58.67 Kb
Page 16
Image 16
TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE ONLY!

True Food Service Equipment, Inc.

MAINTENANCE, CARE & CLEANING

TEMPERATURE CONTROL ADJUSTMENT FOR HIGH ALTITUDE ONLY!

TERMS:

NOTE

Cut-out - Temperature sensed by the controller

Mechanical temperature controllers are affected

 

that shuts the compressor off.

when functioning at high altitude. The Cut-in and

Cut-in - Temperature sensed by the controller

cut-out temperatures will be colder than when the

controller functions closer to sea level.

 

that turns the compressor on.

 

 

TOOLS REQUIRED:

D. For high elevation installations, it may be nec-

essary to "warm-up" the set points. To make

Phillips head screwdriver

the adjustment, insert the appropriate tool in

5/64" or 2 mm Allen wrench

each adjustment screw and turn 1/4 of a revo-

T-7 Torx wrench

lution clockwise (to the right). This procedure

 

 

A. Unplug or disconnect power to the cabinet.

will adjust both the cut-in and cut-out about

2°F warmer.

B. Remove the screws that secure the tempera-

E. Make sure to reconnect the pink wire to prop-

 

ture control to the inset box, lower right, rear

er spade terminal when reinstalling.

 

 

of cabinet.

C.Pull out gently from cabinet.

DANFOSS TEMPERATURE CONTROL

Compressor Connection (pink)

4

3

Cut-out Adjustment Screw Allen (5/64" or 2 mm) (clockwise for warmer)

Cut-in Adjustment Screw Torx (T-7)

(clockwise for warmer)

Compressor Connection (pink)

(double terminal)

To wire temperature control:

connect one pink wire (either one) to terminal 3 and the other pink wire to terminal 4.

14

www.truemfg.com

14

Page 16
Image 16
True Manufacturing Company TCGDZ-50 Temperature Control Adjustment For High Altitude Only, Terms, Tools Required