user manual

TA-500

Parametric Equalisation

Eight sections of equalisation are provided in a similar format to the input channel equalisation; two shelving filters and six parametric.

LMS-D26

Out1 Freq Slope Gain

EQ>- 100Hz 12dB 0.0dB

a b c

a

b

c

Knob A: Frequency, 10.0Hz to 25.6kHz in variable steps

Knob B: Slope, 6 to 12dB / octave in 1dB steps

Knob C: Gain, +/-15dB in 0.2dB steps

The frequency is specified as point where the filter deviates by 3dB from the gain value.

LMS-D26

Out1 Freq Width Gain

EQ1 100Hz 1.4Q 0.0dB

a b c

a

b

c

Knob A, Centre Frequency, 10.0Hz to 25.6kHz in variable steps

Knob B, Width, display selectable, Q or BW (Bandwidth)

BW adjustable from 0.05 to 5 octaves in variable steps

Q adjustable from 14.2 to 0.2 in variable steps

Knob C, Gain, +/-15dB in 0.2dB steps

TA-500 user manual Page 58

Page 58
Image 58
Turbosound TA-500HDP, TA-500TDP, TA-500DP, TA-500HM user manual Out1 Freq Slope Gain EQ- 100Hz 12dB 0.0dB