Design Features Performance

2075DWRR

8Noisy

Cause

a.Copper refrigeration tube touching cabinet

b.Fan blade touching shroud

c.Fan blade obstruction (wiring, foam insulation, packaging material)

9Fresh food or wine temperature too cold

Cause

a.Controller set too cold

b.Defective controller

c.Wiring defect

d.Thermistor not pushed all the way into the well

10Excessive condensation on mullion

Cause

Mullion heater not operating - check resistance

a.Good resistance

b.No resistance

Remedy

a.Carefully adjust tubing

b.Adjust fan mounting or shroud

c.Remove obstruction

Remedy

a.Adjust controller

b.Replace controller

c.Check wiring

d.Check thermistor location

Remedy

a.Bad heater switch

b.Heater wiring

Note: The heater will not operate in ambients over 90° F.

17