REFRIGERATION SYSTEMS
Normal Vapor/Compression Cycle Refrigeration
•Refrigerant is pumped from the compressor to the condenser as a high pressure, high temperature vapor.
•As the refrigerant cools in the high pressure condenser, the vapor condenses to liquid. During this phase change, a great amount of heat is rejected with the help of the condenser fan.
•The liquid then flows to the dryer where it is strained and filtered.
| COMPRESSOR |
CONDENSER | TOP |
COMPARTMENT | |
| THERMISTOR |
| SOLINOID VALVE |
DRYER
SOLINOID VALVE
EVAPORATOR
CAPILLARY TUBE
BOTTOM
COMPARTMENT
THERMISTOR
DRYER
| EVAPORATOR |
CAPILLARY TUBE | DWR052 |
|