Design Features Performance

When checking the thermistors to see if they are reading accurately, it is common to place them in an icebath to see if they read 32°F. Do not place them directly in the water. Use a plastic bag to protect them from moisture. The freezer and ice maker should read 32°F in icewater, however the refrigerator thermistor should read 36°F. There is a built-in 4°F offset in this reading due to its location in the cabinet. This sensor is located outside the refrigerator drawer, which is approximately 4°F colder than the inside of the drawer.

To check the actual temperatures via the display, touch and release the warmer button to view the refrigerator temperature. Hold the colder button, while LED 1 is lit, the freezer temperature will be displayed. Continue holding the colder button, and the display will cycle from freezer to ice maker until the button is released.

POWER

HOT

GAS

ICEMAKER

COMPRESSOR

COND/EVAP

FAN

 

 

 

 

ICEMAKER

 

FREEZER

 

 

SENSOR

 

 

SENSOR 9

 

 

 

 

 

 

 

 

 

 

 

10

POT

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERATOR

2 3

4

5

 

 

 

 

 

 

 

 

SENSOR

1

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

DISPLAY BOARD

-1

 

 

 

 

 

 

 

-2

 

-5

 

 

 

 

 

CONNECTION

-3

-4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOT GAS

 

 

 

 

 

 

 

 

 

 

 

VALVE

 

 

 

 

 

 

 

 

 

J2

 

 

 

 

 

ICEMAKER

 

 

 

 

 

POWER ON

 

1/4" SPADE

 

 

 

 

 

TERMINALS

 

CLRCO035B

This unit can be put into a diagnostic mode.

1.Unplug unit

2.Install jumper on pins 9 and 10 on board.

3.Plug unit back in.

Based on the information listed below, you can turn on and off each relay individually.

Control pot at 0 – CONDENSER/EVAPORATOR FANS

Jumper on 1/4" spade terminals – COMPRESSOR

Jump pins on J2 – HOT GAS VALVE

Jump pins on J2 – ICEMAKER

Example (force a defrost cycle):

Set control pot to 0, Jump pins on J2 for hot gas valve and install jumper on 1/4" spade terminals.