CO2075DWR | Design ■ Features ■ Performance |
When checking the thermistors to see if they are reading accurately, it is common to place them in an icebath to see if they read 32°F. Do not place them directly in the water. Use a plastic bag to protect them from moisture. The freezer and ice maker should read 32°F in icewater, however the refrigerator thermistor should read 36°F. There is a
To check the actual temperatures via the display, touch and release the warmer button to view the refrigerator temperature. Hold the colder button, while LED 1 is lit, the freezer temperature will be displayed. Continue holding the colder button, and the display will cycle from freezer to ice maker until the button is released.
POWER
HOT | GAS | ICEMAKER | COMPRESSOR |
COND/EVAP | FAN |
|
|
|
| ICEMAKER |
| FREEZER | |||||||
|
| SENSOR |
|
| SENSOR 9 | ||||||
|
|
|
|
|
|
|
|
|
|
| 10 |
POT | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| REFRIGERATOR |
2 3 | 4 | 5 |
|
|
|
|
|
|
|
| SENSOR |
1 |
|
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
| DISPLAY BOARD | |||
|
|
|
|
|
|
| |||||
|
|
|
|
|
| CONNECTION | |||||
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| HOT GAS |
|
|
|
|
|
|
|
|
|
|
| VALVE |
|
|
|
|
|
|
|
|
| J2 |
|
|
|
|
| ICEMAKER |
|
|
| |||||
|
| POWER ON |
| 1/4" SPADE |
| ||||||
|
|
|
| TERMINALS |
|
CLRCO035B
This unit can be put into a diagnostic mode.
1.Unplug unit
2.Install jumper on pins 9 and 10 on board.
3.Plug unit back in.
Based on the information listed below, you can turn on and off each relay individually.
Control pot at 0 – CONDENSER/EVAPORATOR FANS
Jumper on 1/4" spade terminals – COMPRESSOR
Jump pins on J2 – HOT GAS VALVE
Jump pins on J2 – ICEMAKER
Example (force a defrost cycle):
Set control pot to 0, Jump pins on J2 for hot gas valve and install jumper on 1/4" spade terminals.
42