2075DWRWC | Design ■ Features ■ Performance |
3Drawers will not close properly
•The drawer slides contain a
4Cascade parts not operating properly
•The cam on the cascade mechanism should automatically reset as the drawer is moved fully in and out. If it does not, manually reset cam.
If the drawer will not close, make sure the cascading cams are positioned correctly. The drawer will not close if the cams are in the A “open” position. Reset the cams manually as shown in position B “closed.” The drawers should take a minimal amount of effort to close. See illustration on page 33.
5LED dot lit on display
•This light indicates that a thermistor has gone out of range. If the unit is still working the thermistor is now operational. Unplug unit and plug back in, to clear light. If unit is still not working, change board and thermistors.
6Trouble with lights
•Each light is controlled by a switch that operates when the drawer is opened and by a touchsensor in the glass.
•Check wiring.•Check bulb.7Display not functioning
•Red LED on rear of display indicates the display has power.•Flashing green indicates communication with main board.•If either is not lit, check wiring to main board.•Could be in Sabbath mode.8Not cooling
•Check solenoid valves and connections.32