TROUBLESHOOTING

! WARNING !

DO NOT service the unit until the main electrical power has been disconnected.

2075DWRWC

Before servicing this unit, take readings from the electronic control (refer to The Electronic Temperature Control for checking actual temperatures, if needed). These actual readings are important to take before having the drawers open for more than 30 seconds to obtain accurate readings.

Top drawer temperature: __________This temperature should be within a few degrees of the setpoint.Bottom drawer temperature: _________

This temperature should be within a few degrees of the setpoint.

If there is a dot illuminated above the temperature display, there has been a problem with the thermistor. If you can read the actual temperatures then the problem has been corrected. If you were unable to read the temperatures or if you read 99, then the thermistor is not working and the circuit board and thermistors must be changed. The thermistor harness is matched to the circuit board and these must be changed as an assembly.

1Temperatures not cold enough

Check actual temperatures versus setpoint. After 24 hours of runtime, temperatures should be with- in a few degrees of setpoint.

Drawers left open or not sealing properly.Clean condenser.

2Temperatures too cold

Check actual temperatures versus setpoint.Ensure thermistors are pushed all the way into the well tube.

If top drawer is well below setpoint and the lower drawer is not achieving setpoint the thermistors may be switched.

If bottom drawer is well below setpoint and the upper drawer is not achieving setpoint the valve power wires may be switched.