Uniden manual BCT8 8/13/03 514 PM

Models: BCT8

1 65
Download 65 pages 22.22 Kb
Page 58
Image 58

BCT8 8/13/03 5:14 PM Page 54

If you experience difficulty while in TrunkTracker mode, try the following steps.

Problem

 

Suggestion

 

 

 

Scanner won't track.

1.

Missing the Data Frequency.

 

2. Change to a Type 1 Scanner setup.

 

 

Review Fleet Map Programming on page 45.

 

 

Scanner won't stop

1. No IDs have been programmed.

during Scan List mode.

2.

The IDs you have stored are not active.

 

 

Scanner will not acquire

1. Adjust the squelch for Trunking mode - refer to page 29.

data channel.

2.

Missing the frequency used for the data channel.

 

 

Check your frequency list.

 

 

 

Missing replies to

1.

Change a Type 1 scanner setup.

conversations.

 

Review Fleet Map Programming on page 44.

 

2.

Try another Preset Fleet Map or Program your own Fleet Map.

 

3.

Check to see that all of the system's frequencies have been entered.

 

 

 

Channel Activity

1.

May be a telephone interconnect call, which are intentionally blocked by

Indicators are flashing

 

your scanner.

but no sound is heard.

2.

The ID on your display is not active.

 

 

 

Scanner not tracking an

1.

Logical channel numbers (frequencies) for the system are not programmed

EDACS system properly.

 

in the correct order. Check frequency resources and reprogram.

 

2.

Not all frequencies for the system are programmed.

 

 

Check frequency resources.

 

 

 

If you still cannot get satisfactory results while using your scanner or if you want additional information, please call or write the Uniden Parts and Service Division. The address and phone number is listed in the warranty at the end of this manual. If you would like immediate assistance, please call Customer Service at (800)297-1023.

If you have internet access, you can visit scanner.uniden.com for additional information.

54

Page 58
Image 58
Uniden manual BCT8 8/13/03 514 PM