| SPECIFICATIONS | |||
Natural Gas |
|
|
|
|
|
|
|
|
|
Manifold Pressure Setting 4" w.c. |
|
|
|
|
|
|
| ||
Gas Inlet Pressure | Maximum |
|
|
|
|
|
| ||
| Minimum 5" w.c. |
|
|
|
|
|
| ||
|
|
|
| Gas Rate |
|
| Number | ||
|
|
|
|
| |||||
Model Number |
| Type | Max BTU/Hr |
| Min BTU/Hr |
|
| of Burners | |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
9945N |
|
| Manual | 39,900 |
| 27,000 |
|
| 1 |
Propane / LPG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c. |
| ||||||||
Manifold Pressure Setting 10" w.c. |
|
|
|
|
|
|
| ||
Gas Inlet Pressure | Maximum 13" w.c. |
|
|
|
|
|
| ||
| Minimum 11" w.c. |
|
|
|
|
|
| ||
|
|
|
| Gas Rate |
|
| Number | ||
|
|
|
|
| |||||
Model Number |
| Type | Max BTU/Hr |
| Min BTU/Hr |
|
| of Burners | |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
9945L |
|
| Manual | 39,900 |
| 27,000 |
|
| 1 |
|
|
|
|
|
|
|
|
|
|
Controls - Main control has 4 positions:
1.OFF - All gas to the burner is shut off at the control
2.IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3.PILOT - Valve position to light/maintain a standing pilot
4.ON - Gas flow to complete system.
HIGH / LOW Control - Infinite control :
Rotate knob clockwise to LOW, counter clockwise to HIGH.
CONTENTS
9945L and 9945N Unvented Gas Heaters
1.Packet containing Homeowners/Installation instructions.
2.Three(3) individually wrapped fiber ceramic logs, refer to installation instructions.
3.Unvented gas heater.
CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED
CAUTION
GLOVESARERECOMMENDEDWHENHANDLINGCERAMICFIBERLOGS TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS. LOGS ARE FRAGILE, HANDLE WITH CARE.
Carefully inspect the contents for shipping damage and immediately inform your dealer if any damage is found.
5