COM4
Pin # | Assignment | Pin # | Assignment |
1 | DCD | 2 | RXD |
3 | TXD | 4 | DTR |
5 | Ground | 6 | DSR |
7 | RTS | 8 | CTS |
9 | RI | 10 | Ground |
11 | TXD+ | 12 | TXD- |
13 | RXD+ | 14 | RXD- |
yCOM4 Figure:
14
13
2
1
Note: How to connect a RS485 device with the COM port ribbon cable?
Our Industrial Board encloses a COM port ribbon cable for internal connection. RS422/485 device must connect to downside
For | Connector |
|
1 | 5 | |
|
| 1: TXD- |
|
| 2: TXD+ |
6 | 9 | 3: RXD- |
4: RXD+ |
5: GND
For
Installation • 23