__ (c) On one column of the block, completely punch down a 25 pair cable. The other end of the cable should have a female amphenol connector.

__ (d) Plug the amphenol connector into the V-1101A.

__ (e) Mark the punch down block as shown in Figure 2.

Power Connections

__ 1.

Unplug power supply.

__ 2.

Connect –24 Vdc "B" battery (may be

 

referred to as "–" or "signal battery") from

 

power supply to BB (S/V) of the V-1101A.

__ 3.

Connect –24 Vdc Ground ("B" ground, "+",

 

or "signal" ground) from the power supply to

 

BG (V/S).

__ 4.

Connect –24 Vdc "A" battery (may be

 

referred to as "–" or "talk battery") from the

 

power supply to AB (BR/V) of the

 

V-1101A.

__ 5.

Connect –24 Vdc Ground ("A" ground, "+",

 

or "talk ground") from the power supply to

 

AG (V/BR).

__ 6.

Connect GROUND from the power supply

 

to a good Earth or Water Pipe ground.

7.Power Test:

__ (a) Plug in power supply.

__ (b) Using a screwdriver, momentarily short between the BFT (W/S) and BFR (S/W) leads of the V-1101A and listen for a relay to operate in the unit.

__ (c) If no relay is heard:

__ (1) Unplug power supply.

__ (2) Verify the V/BR and V/S pairs are

properly connected at the punch-down block and in the amphenol.

__ (3) Return to step 2, and verify all connections.

__ (d) If a relay is heard, proceed to step 8. __ 8. Unplug power supply.

Connecting Arrangements

NOTE: Place a check by the arrangement being used and proceed to the Figure indicated for step-by-step installation instructions.

__ 1. Electronic key system line key access: Proceed to Figure 3.

__ 2. PABX loop trunk port access: Proceed to Figure 3.

__ 3. 1A2 key system line button access: Proceed to Figure 4.

__ 4. 1A2 key system intercom access: Proceed to Figure 5.

__ 5. Electronic key or PABX page port access: Proceed to Figure 6.

4

947101

Page 4
Image 4
Valcom V-1101A specifications Power Connections, Connecting Arrangements