SAFETY INFORMATION PRODUCT IDENTIFICATION
3
SAFETY INFORMATION
Continued
1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.
3.If you smell gas
•shut off gas supply
•do not try to light any appliance
•do not touch any electrical switch; do not use any phone in your building
•immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
•if you cannot reach your gas supplier, call the fire department
4.This fireplace shall not be installed in a bedroom or bathroom.
5.Do not use this fireplace as a
6.Do not add extra logs or ornaments such as pine cones, ver- miculite, or rock wool. Using these added items can cause soot- ing. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.
7.This fireplace is designed to be smokeless. If logs ever appear to smoke, turn off fireplace and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and fireplace burning manufacturing residues.
8.To prevent the creation of soot, follow the instructions in Clean- ing and Maintenance, page 19.
9.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls or furniture.
10.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If fireplace keeps shutting off, see Trouble- shooting, pages 20 through 22.
11.Do not run fireplace
•where flammable liquids or vapors are used or stored
•under dusty conditions
12.Do not use this fireplace to cook food or burn paper or other objects.
13.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the fireplace and to replace any part of the control sys- tem and any gas control which has been under water.
14.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped
15.Turn fireplace off and let cool before servicing. Only a quali- fied service person should service and repair fireplace.
16.Operating fireplace above elevations of 4,500 feet could cause pilot outage.
17.To prevent performance problems, do not use propane/LP fuel tanks of less than 100 lbs. capacity.
18.Provide adequate clearances around air openings.
PRODUCT IDENTIFICATION
Crossover Log
Middle Log
Front Log | Rear Log |
| |
| Rear |
| Burner |
Front Burner |
|
Figure 1 - Log Base Assembly, Split Oak Set
Top Louver | Top Outer | |
Assembly | ||
Casing | ||
Fireplace | ||
| ||
Hood |
| |
Firebox |
| |
Support |
|
Optional Blower
Assembly
(Not Included)
Screen
Assembly
Bottom Louver
Assembly
Figure 2 - Fireplace