OPERATING FIREPLACE -
Variable Control Operation
To Turn Off Gas to Appliance
Manual Lighting Procedure
Blower Operation
17
OPERATING FIREPLACE
Continued
VARIABLE CONTROL
OPERATION
The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher settings pro- ducesgreaterheatoutput.Thisresultsinincreasedheatingcomfort.
WARNING: Do not operate heater between locked positions.
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. | Turn control knob clockwise Clockwise to the HIGH position. | |
2. | Slightly depress control knob and turn clockwise | Clockwise |
| to the PILOT position. |
|
3. | Slightly depress control knob and turn clockwise | Clockwise |
| to the OFF position. |
|
Shutting Off Burners Only (pilot stays lit)
1. Turn control knob clockwise Clockwise to the HIGH position.
2.Press in and turn clockwise Clockwise to the PILOT position.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 5 under Lighting Instructions, page 16.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, page 16.
BLOWER OPERATION
MODEL VSGF28PTC
WARNING: This fireplace has a
Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower left inside louver door.
This
Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.
MODEL VSGF28PV
Blower Kit Model GA3750 Series
This optional
IMPORTANT: Light your gas appliance with the blower off.
Note: Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions.
Follow installation instructions included with the blower accessory.
Blower Kit Model GA3650T Series
Locate the blower switch by opening the lower louver on fire- place. Blower switch is located at lower left inside louver door.
The GA3650T
IMPORTANT: Light your gas appliance with the blower off.
Note for GA3650T: If you are using GA3650T blower, your gas fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fire- place.
Note: Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions.
Follow installation instructions included with the blower accessory.
For morevisit www..com