TECHNICAL

TECHNICAL

You may have further questions about installation, operation, or troubleshooting.

If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

SERVICE

 

 

SPECIFICATIONS Input Rate

10,000 Btu/Hr

 

Type Gas

Natural Only

 

Ignition

Piezo

 

Pressure Regulator Setting

3" W.C.

 

Inlet Gas Pressure (in. of water) *

 

 

Maximum

10.5"

 

Minimum

5"

 

Dimensions, Inches (H x W x D)

257/8 x 2613/16 x 93/8

 

Fireplace (including hood and screws)

 

Carton

325/8 x 273/16 x 115/8

 

Weight, pounds

441/2 lbs.

 

Fireplace

 

Shipping

48 lbs.

 

* For purposes of input adjustment

 

SERVICE

When gas pressure is too low

 

• pilot will not stay lit

 

HINTS

 

• burner will have delayed ignition

 

 

• fireplace will not produce specified heat

 

 

When gas quality is bad

 

 

• pilot will not stay lit

 

 

• burner will produce flames and soot

 

 

• fireplace will backfire when lit

 

 

You may feel your gas pressure is too low or gas quality is bad. If so, contact your

 

local natural gas supplier.

 

REPLACEMENT

Note: Use only original replacement parts. This will protect your warranty coverage

for parts replaced under warranty.

 

PARTS

Parts Under Warranty

 

 

Contact authorized dealers of this product. If they can’t supply original replacement

 

part(s) call DESA International’s Technical Service Department at 1-800-323-5190

 

for referral information.

 

When calling DESA International, have ready

your name

your address

model number of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your fireplace