CLEANING AND MAINTENANCE

TROUBLE-

SHOOTING

Note: All troubleshooting items are listed in order of operation.

WARNING

WARNING ICON

G 001

Turn off fireplace and let cool before cleaning.

CAUTION

WARNING ICON

G 001

You must keep control areas, burner, and circulating air passage- ways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

WARNING

WARNING ICON

G 001

Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.

CAUTION

WARNING ICON

G 001

Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

When ignitor button

1.

Ignitor cable pinched or

1.

Free ignitor cable if

is pressed, there is no

 

wet

 

pinched by any metal or

spark at ODS/pilot

 

 

 

tubing. Keep ignitor

 

 

 

 

cable dry

 

2.

Ignitor electrode not con-

2.

Reconnect ignitor cable

 

 

nected to ignitor cable

 

 

 

3.

Broken ignitor cable

3.

Replace ignitor cable

 

4.

Bad piezo ignitor

4.

Replace piezo ignitor

 

5.

Ignitor electrode broken

5.

Replace ignitor

 

6.

Ignitor electrode posi-

6.

Replace ignitor

 

 

tioned wrong

 

 

24

103670

Page 24
Image 24