CLEANING AND MAINTENANCE
TROUBLE-
SHOOTING
Note: All troubleshooting items are listed in order of operation.
WARNING
WARNING ICON | G 001 |
Turn off fireplace and let cool before cleaning.
CAUTION
WARNING ICON | G 001 |
You must keep control areas, burner, and circulating air passage- ways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.
ODS/PILOT AND BURNER
• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air to clean.
Exterior
•Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.
WARNING
WARNING ICON | G 001 |
Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.
CAUTION
WARNING ICON | G 001 |
Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
OBSERVED | POSSIBLE |
|
| |
PROBLEM | CAUSE | REMEDY | ||
|
|
|
|
|
When ignitor button | 1. | Ignitor cable pinched or | 1. | Free ignitor cable if |
is pressed, there is no |
| wet |
| pinched by any metal or |
spark at ODS/pilot |
|
|
| tubing. Keep ignitor |
|
|
|
| cable dry |
| 2. | Ignitor electrode not con- | 2. | Reconnect ignitor cable |
|
| nected to ignitor cable |
|
|
| 3. | Broken ignitor cable | 3. | Replace ignitor cable |
| 4. | Bad piezo ignitor | 4. | Replace piezo ignitor |
| 5. | Ignitor electrode broken | 5. | Replace ignitor |
| 6. | Ignitor electrode posi- | 6. | Replace ignitor |
|
| tioned wrong |
|
|
24
103670