Vanguard Heating VMH10TN Trouble, Shooting, If you smell gas, Shut off gas supply, Continued

Models: VMH10TN

1 32
Download 32 pages 37.64 Kb
Page 27
Image 27
TROUBLE-

TROUBLE-

WARNING ICONG 001WARNING

SHOOTING

 

If you smell gas

Continued

• Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

 

OBSERVED

POSSIBLE

 

 

 

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

 

 

Fireplace produces a

1.

Metal expanding while

1.

This is common with

 

clicking/ticking noise

 

heating or contracting

 

most fireplaces. If noise

 

just after burner is lit

 

while cooling

 

is excessive, contact

 

or shut off

 

 

 

qualified service person

 

 

 

 

 

 

 

 

Fireplace produces

1.

Fireplace burning

1.

Ventilate room. Stop

 

unwanted odors

 

vapors from paint, hair

 

using odor causing

 

 

 

spray, glues, etc. (See

 

products while fire-

 

 

 

IMPORTANT statement

 

place is running

 

 

 

above)

2.

Locate and correct all

 

 

2.

Gas leak. See Warn-

 

leaks (see Checking Gas

 

 

 

ing statement at

 

Connections, page 17)

 

Fireplace shuts off in

 

top of page

1.

Open window and/or

 

 

 

 

use (ODS operates)

1.

Not enough fresh air is

 

door for ventilation

 

 

 

available

2.

Contact local natural

 

 

2.

Low line pressure

 

gas company

 

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

 

Cleaning and Mainte-

 

 

 

clogged

 

nance, page 24)

 

 

 

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

 

control knob is in

 

leaks (see Checking Gas

 

OFF position

 

ing statement at

 

Connections, page 17)

 

 

 

top of page

2.

Replace control valve

 

Gas odor during

2.

Control valve defective

1.

Take apart gas tubing

 

1.

Foreign matter be-

 

combustion

 

and remove foreign

 

 

 

tween control valve

 

matter

 

 

 

and burner

2.

Locate and correct all

 

 

2.

Gas leak. See Warn-

 

leaks (see Checking Gas

 

 

 

ing statement at

 

Connections, page 17)

 

Moisture/condensa-

 

top of page

1. Refer to Air for Combus-

 

1.

Not enough combus-

 

tion noticed on

 

tion and Ventilation re-

 

windows

 

tion/ventilation air.

 

quirements

 

 

 

 

 

(page 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

103670

Page 27
Image 27
Vanguard Heating VMH10TN Trouble, Shooting, If you smell gas, Shut off gas supply, Connections, page, Continued