Vanguard Heating VMH10TNB Installation, Continued, Connecting Fireplace To Gas Supply

Models: VMH10TNB

1 28
Download 28 pages 40.09 Kb
Page 15
Image 15
CONNECTING FIREPLACE TO GAS SUPPLY

OWNER’S MANUAL

INSTALLATION

Continued

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove screws that attach branch sup- port to fireplace (see Figure 24). Care- fully lift up branch support and remove from fireplace (see Figure 24).

3.Route flexible gas line (provided by installer) from equipment shutoff valve into fireplace through side or rear ac- cess holes in outer casing. Route flex- ible gas supply line through fireplace access holes in outer casing.

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 25). The flexible gas supply line con- nection to the equipment shutoff valve should be accessible.

4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line (see Figure 25). Con- nect flexible gas line to flexible gas line attached to gas regulator of fireplace (see Figure 25).

5.Check all gas connections for leaks. See Checking Gas Connections, page 16.

6.Replace branch support back into fire- place. Feed flexible gas line into fire- place base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reat- tach branch support to fireplace with screws removed in step 2.

Branch

Support

Shoulder

Screw

Flexible Gas

Line

Screen

Figure 24 - Removing Log Base Assembly From Fireplace

To Fireplace

Gas Connector

 

 

 

 

 

 

 

 

 

Gas Regulator

Equipment Shutoff Valve

 

 

Flexible Gas Line from

 

 

To Gas

 

Supply

Fireplace Gas Regulator

Flexible Gas Line from

 

Provided With Fireplace

 

Equipment Shutoff Valve

 

Provided By Installer

Figure 25 - Attaching Flexible Gas Lines Together

Continued

107031

15

Page 15
Image 15
Vanguard Heating VMH10TNB installation manual Continued, Connecting Fireplace To Gas Supply, Installation Items Needed