Vanguard Heating VSGF-28PTE Installation, WARNING This appliance, requires a 1/2 NPT National

Models: VSGF-28NTE VSGF-28PTE

1 32
Download 32 pages 26.3 Kb
Page 12
Image 12
WARNING: This appliance

INSTALLATION

Continued

2.If using blower, install and properly ground GA3555, three-prong 120 volt electrical outlet, in fireplace. Follow instructions included in kit.

3.Install gas piping into fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equip- ment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, column 2.

4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

5.Plug electrical cord into electrical outlet installed in step 2.

6.Carefully insert fireplace into rough opening.

7.Attach flexible gas line to gas supply. See Con- necting Fireplace to Gas Supply, page 14.

8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 15).

9.Check all gas connections for leaks. See Checking Gas Connections, page 15.

10.Install trim after final finishing and/or painting of wall (see Figure 7, page 9).

Nails or

Wood

Screws

Nailing

Flanges

Figure 15 - Attaching Fireplace to Wall

Studs

Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

If your installation does not meet the below mini- mum clearances, you must:

raise the mantel to an acceptable height,

OR

remove the mantel.

10"

 

Mantel Shelf

 

 

 

8"

 

 

 

 

6"

 

 

 

 

2

1

/2"

 

 

 

 

 

 

 

Minimum Non-

 

 

 

 

 

Combustible

 

 

 

 

 

Material

 

13"

16"

19"

21"

 

 

 

 

 

Note: All Vertical

 

 

 

measurements are

 

 

 

from top of fireplace

 

 

 

opening to bottom

 

 

 

of mantel shelf.

Figure 16 - Minimum Mantel Clearances

for Built-In Installation

INSTALLING GAS PIPING TO

FIREPLACE LOCATION

 

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A

qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

 

 

 

CAUTION: Never connect

propane/LP fireplace directly

to the propane/LP supply. This

heater requires an external regu-

lator (not supplied).

Install the

external regulator between the

heater and propane/LP supply.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

 

 

 

12

www.desatech.com

113135-01C

Page 12
Image 12
Vanguard Heating VSGF-28PTE Installation, WARNING This appliance, requires a 1/2 NPT National, the pressure regulator