Vanguard Heating VSGF-28NTE Operating Fireplace, WARNING You must operate, Lighting Instructions

Models: VSGF-28NTE VSGF-28PTE

1 32
Download 32 pages 26.3 Kb
Page 17
Image 17
OPERATING FIREPLACE

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

FOR YOUR SAFETY WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information, col- umn 1.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise LIGHTING to the OFF position (see Figure 28).

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you donʼt smell gas, go to the next step.

5.Turn control knob counterclockwise WARNING:You must operate to the PILOT position. Press in control knob for five (5) seconds (see Fig- ure 28).

Note: If running fireplace for first time, there will be air in gas line. You may need to press in control knob for 30 seconds or longer. This will allow air to bleed from the gas system.

6.Continue pressing control knob in. Press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 18.

WARNING:You must operate

 

this fireplace with the fireplace

 

screen in place. Make sure fire-

 

place screen is installed before

 

running fireplace.

 

Ignitor Button

Control

Knob

Figure 28 - Control Knob and Ignitor
Button Location

113135-01C

www.desatech.com

17

Page 17
Image 17
Vanguard Heating VSGF-28NTE, VSGF-28PTE Operating Fireplace, WARNING You must operate, this fireplace with the fireplace