Vanguard Heating VSGF-28NTE Product Identification, Unpacking, Product Features, Operation

Models: VSGF-28NTE VSGF-28PTE

1 32
Download 32 pages 26.3 Kb
Page 5
Image 5
PRODUCT

PRODUCT

IDENTIFICATION

Middle Log

Rear Burner

 

Rear

Front

Log

 

Log

 

Front Burner

Figure 1 - Log Base Assembly, Split Oak Set

Top Louver

Top Outer

Assembly

Casing

Fireplace

 

Hood

 

Firebox

 

Support

 

Screen

Assembly

Bottom Louver

Blower

Assembly

Assembly

Figure 2 - Fireplace

UNPACKING

Figure 2 - Fireplace CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important warranty and safety information.

1.With utility knife, cut the carton all the way around above the staples on the bottom tray. Lift the carton off the heater. Remove packing. Note: The hood is located in the packing on the right hand side of the heater front. Lift the heater off the bottom tray.

2.Locate two screws above top corners of the fireplace screen. Remove and discard these screws. Lift fireplace screen up and pull out to remove.

3.Remove protective packaging applied to logs, log base assembly, and fireplace.

4.Remove fireplace hood from carton insert.

5.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought fireplace.

PRODUCT FEATURES

OPERATION

This vent-free fireplace is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing embers. When used without the blower, the fireplace requires no electricity making it ideal for emergency backup heat.

SAFETY DEVICE

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/ pilot is a required feature for vent-free room heat- ers. The ODS/pilot system shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace.

BLOWER ASSEMBLY

This fireplace has a blower assembly. The blower operates thermostatically and has a variable speed control. The blower circulates heated air from the fireplace into the room. Use of blower is optional.

THERMOSTAT CONTROL

This fireplace has a thermostat sensing bulb and a control valve. The thermostat controls the heat output and flame height. This maintains a consis- tent room temperature. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher comfort settings al- lows fireplace to run longer, producing greater heat output. At lower comfort settings, the fireplace will run less. This results in increased heating comfort. This can also result in lower gas bills.

113135-01C

www.desatech.com

5

Page 5
Image 5
Vanguard Heating VSGF-28NTE Product Identification, Unpacking, Product Features, Operation, Safety Device, Blower Assembly