3

Springfingers

Figure 3-2Load Board (Enterprise 6000 Systems Only)

3.3 Hot-Plug Feature

!

!

Enterprise systems have extensive error detection mechanisms, and an Automatic System Reconfiguration (ASR) feature that enables the system to be rebooted with failed components (such as CPUs, memory, or I/O) disabled. When an error is detected, the system can be reconfigured so that the board containing the failed components is placed in low power mode and is no longer accessible.

Caution – The peripheral power supply provides the precharge voltages required for hot-plug. Do not attempt hot-plug of a system component if the power supply is missing or inoperative. Use prtdiag(1M)to determine the status of the peripheral power supply.

Caution – If the message: NOTICE: Hot Plug not supported in this system is displayed during boot, do NOT attempt hot-plug in this system or damage to the hardware will occur.

3-4

Ultra Enterprise 6000/5000/4000 Systems ManualNovember 1996

Page 52
Image 52
Sun Microsystems 6.0005E+11 manual Hot-Plug Feature, 2Load Board Enterprise 6000 Systems Only