3

5.If a board is not immediately replaced, a load board (Enterprise 6000 systems only) or a filler panel (Enterprise 4000 and 5000 systems only) must be installed in its place.

See Section 3.2, “Filler Panels and Load Boards.”

3.5.2.2Removing a Board from a Nonpowered On System

1.Use a Phillips #1 screwdriver to mechanically release the board from the system card cage.

Insert the screwdriver into each quarter-turn access slot (the slots are located on the left and right sides of the board front panel) and then turn a quarter turn so that the arrow points to the unlocked position. See Figure 3-8.

2.Unfasten any cable connectors from the front panel and set them aside. Label cables to identify them for reconnection later.

3.Pull the ends of both extraction levers outward simultaneously to unseat the board from the centerplane receptacles.

See Figure 3-9 for positioning of extraction levers.

3.5.3Installing a Board

3.5.3.1Board Slot Selection

Note – Logically there is no difference between the board slots in the front or rear of the card cage, and each slot can accept any board type. It is suggested that CPU/Memory boards be installed in the front slots, and I/O and disk boards be installed in the rear slots because of cabling. Should the need arise, however, any of these three board types can be placed in any of the numbered board slots, with the exception of slot 1. Slot 1 should be used by the first I/O board because it is the only slot connected to the onboard SCSI devices.

The first CPU/Memory board is placed in slot 0, followed sequentially by all remaining even numbered slots. If there are boards remaining, they can be installed sequentially in odd numbered slots, if available, in the system rear (with the exception of slot 1 as noted above). See Figure 3-10 and Figure 3-11.

3-14

Ultra Enterprise 6000/5000/4000 Systems ManualNovember 1996

Page 86
Image 86
Sun Microsystems 6.0005E+11 manual Installing a Board