A

Table A-8Standalone Server Electrical Specifications (Continued)

Parameter

 

Value

BTU rating

 

4680 BTU

Power factor

 

0.92 - 0.96

Plug type

U.S.

NEMA 5-15P

 

International

10A, single phase IEC 320,

 

 

connected for 220-240 Vac

 

 

 

A.3 Environmental Requirements

Table A-9Cabinet Server Temperature, Humidity,

and Altitude Limits

 

Operating

Nonoperating

Temperature

41°F to 95°F (5°C to 35°C)*

-4°F to 140°F (-20°C to 60°C)

Humidity

20% to 80% RH noncondensing,

93% RH

 

27C max wb

 

Altitude

9,843 ft (3 km)

39,370 ft (12 km)

*Maximum operating temperature is 95°F (35°C) when using tape media.

Table A-10Standalone Server Temperature, Humidity,

and Altitude Limits

 

Operating

Nonoperating

Temperature

41°F to 104°F (5°C to 40°C)*

-4°F to 140°F (-20°C to 60°C)

Humidity

20% to 80% RH noncondensing,

93% RH

 

27C max wb

 

Altitude

9,843 ft (3 km)

39,370 ft (12 km)

*Maximum operating temperature is 95°F (35°C) when using tape media.

A-4

Ultra Enterprise 6000/5000/4000 Systems ManualNovember 1996

Page 224
Image 224
Sun Microsystems 6.0005E+11 manual Environmental Requirements, Operating Nonoperating