10
10.6 | Defective Disk Drive |
|
| |
Begin |
| INDICATION | TEST/PROCEDURE | REFERENCE |
|
| System error message or |
|
|
|
| device code identifies a |
|
|
|
| specific fault |
|
|
|
|
| Check /var/adm/messages |
|
|
|
|
| |
|
|
| Halt access to device and power | Internal drives: Chapter 6, “Clock |
|
|
| down the device or tray. | Board. “ |
|
|
| Set ID code (if used) on | Tray: see tray service manual. |
|
|
| replacement device before | Refer to drive or tray documentation for |
|
|
| installing. | ID code. |
|
|
| If replaced unit is SPARCstorage | Refer to SPARCstorage Array |
|
|
| Array disk tray or the tray | documentation. |
|
|
| controller board, reset |
|
|
| Device not identified or |
| |
|
| intermittent problem |
|
|
Run SunVTS.
For SCSI device, use OpenBoot
Check cable connection.
If replaced unit is SPARCstorage Array disk tray or the tray controller board, reset
Refer to SunVTS User’s Guide.
End
Figure 10-6 Diagnosing Disk Drive Problems
Flow Diagrams for Troubleshooting |