3

7.Place the SBus card in an antistatic bag.

8.If the SBus card is not immediately replaced, install a filler panel (part number 340-2305) on the I/O board back panel opening. To secure the filler panel, use the screws that were removed in Step 3.

Caution Be sure to install the filler panel right-side up. Installing it upside

!down creates a gap at the top edge of the SBus slot opening that can impair system cooling and FCC regulatory compliance.

9.Replace the I/O board. Use the procedures in Section 3.5.3, “Installing a Board.”

3.5.4.3Preparing to Install an SBus Card

Note – If the new SBus card does not have an adapter plate or the Link Integrity Test feature, proceed to “Installing an SBus Card” on page 3-26.

1.Attach a wrist strap and take the SBus card out of the protective packaging and place the SBus card on an antistatic mat.

2.Remove the adapter bracket from the SBus card rear panel.

See Figure 3-16. Remove the two screws securing the adapter to the card rear panel (the adapter bracket and the screws are not needed for this installation).

Remove adapter

Remove screws

Figure 3-16SBus Card Rear Panel with Adapter

I/O Boards and Components

3-23

Page 95
Image 95