5.3. Preset Memory Recall

Recalls any desired preset memories. 9000Series Amplifier responds with the same data as that received.

Note:

Settings to be stored in preset memories are referred to as “SCENE” in mixer mode and “EVENT” in matrix mode.

In 'Matrix mode', the command of 'EVENT end' is not provided.

Therefore, it is recommended to use ‘Preset memory recall’ command only for Mixer mode ‘SCENE’ activation.

In the case of using this command for ‘EVENT’ activation in Matrix mode, use the following to end the ‘EVENT’ before activating other Events. Otherwise, EVENT priorities will not be controlled properly.

To turn off the activation ‘EVENT’ in matrix mode, use one of the following procedures:

1)Use a busy signal (such as a contact closure) from external equipment (if available) connecting to any control input terminal of The 9000 series Amplifier to sense busy status using the busy input terminal setting.

2)Turn off the assigned input channel by using ‘Channel ON/OFF’ command (see section 5.4 channel ON/OFF). Be sure to turn on the input channel again for next use. In this case, all of the other EVENTS related to that input channel will also be turned off.

Note: Preset Memory Recall command cannot be received during power off.

F1H, 02H, 00H, <Preset Number>

<Preset Number> 00H - 1FH: Preset Number 1 - 32

Note: During single channel operation or BGM/PAGE operation in matrix mode

00H - 07H: Preset Number 1 - 8

Example 1: Recalling Preset Memory 1

F1H, 02H, 00H, 00H

Example 2: Recalling Preset Memory 2

F1H, 02H, 00H, 01H

Page 11 of 24

Page 11
Image 11
Vax RS 232C manual Preset Memory Recall