5.7. EQ Settings

Perform EQ settings (ON/OFF, Band number, Gain, Q and Center frequency) of the input/output channels. 9000Series Amplifier responds with the same data as that received. Band number, Gain, Q, and Center frequency cannot be received when EQ is set to OFF. They can be valid only when EQ is set to ON.

Note: Command cannot be received during power off.

A1H, 07H, <Channel Attribute>, <Channel Number>, <OFF/ON>, <Band Number>, <Gain Value>, <Q Value>, <Freq Value>

<Channel Attribute>

00H: Input channel

01H: Output channel

<Channel Number>

00H - 07H (Input channel 1 - 8)

00H - 07H (Output channel 1 - 8)

<OFF/ON> 00H: EQ OFF

01H: EQ ON

<Filter Number>

00H - 09H: Filter 01 - 10

<Gain Value>

EQ-GAIN TABLE

Value

Gain (dB)

Value

Gain (dB)

HEX

DEC

 

HEX

DEC

 

00H

0

-12

0DH

13

+1

01H

1

-11

0EH

14

+2

02H

2

-10

0FH

15

+3

03H

3

-9

10H

16

+4

04H

4

-8

11H

17

+5

05H

5

-7

12H

18

+6

06H

6

-6

13H

19

+7

07H

7

-5

14H

20

+8

08H

8

-4

15H

21

+9

09H

9

-3

16H

22

+10

0AH

10

-2

17H

23

+11

0BH

11

-1

18H

24

+12

0CH

12

0

 

 

 

Note: If testing using Hyperterminal HEX value 0DH may incorrectly translate and will not work. But when used in other applications using the HEX 0DH will work.

Page 15 of 24

Page 15
Image 15
Vax RS 232C manual EQ-GAIN Table, EQ Settings