<Q Value>

EQ-Q TABLE

Value

Q

HEX

DEC

 

00H

0

0.3

01H

1

0.5

02H

2

0.7

03H

3

1

04H

4

1.5

05H

5

2

06H

6

3

07H

7

5

<Freq Value>

EQ-FREQUENCY TABLE

 

Value

Freq (Hz)

Value

Freq (Hz)

 

 

HEX

DEC

 

HEX

DEC

 

 

 

00H

0

20

11H

13

1k

 

 

01H

1

25

12H

14

1.25k

 

 

02H

2

31.5

13H

15

1.6k

 

 

03H

3

40

14H

16

2k

 

 

04H

4

50

15H

17

2.5k

 

 

05H

5

63

16H

18

3.15k

 

 

06H

6

80

17H

19

4k

 

 

07H

7

100

18H

20

5k

 

 

08H

8

125

19H

21

6.3k

 

 

09H

9

160

1AH

22

8k

 

 

0AH

10

200

1BH

23

10k

 

 

0BH

11

250

1CH

24

12.5k

 

 

0CH

12

315

1DH

25

16k

 

 

0DH

13

400

1EH

26

20k

 

 

0EH

14

500

 

 

 

 

 

0FH

15

630

 

 

 

 

 

10H

16

800

 

 

 

 

Example:

Setting the Input Channel 1’s EQ to ON, Band No. to 1, Gain value to +2 dB, Q

 

 

value to 0.7 and Center frequency to 40 Hz.

 

 

A1H, 07H, 00H, 00H, 01H, 00H, 0EH, 02H, 03H

Page 16 of 24

Page 16
Image 16
Vax RS 232C manual EQ-Q Table, EQ-FREQUENCY Table