5.10. Input Sensitivity Setting

Performs input sensitivity setting of Input channel. 9000Series Amplifier responds with the same data as that received. Input sensitivity setting is enabled only for the channel on which the D-001T or AN-001T is used.

Note: Command cannot be received during power off.

ACH, 02H, <Channel Number>, <Value>

<Channel Number>

00H - 07H (Input channel 1 - 8)

<Value >

INPUT SENSITIVITY TABLE

Value

 

Sense

 

Value

 

Sense

 

HEX

DEC

 

(dB)

 

HEX

DEC

 

(dB)

 

00H

0

-10

 

05H

5

-42

 

01H

1

-18

 

06H

6

-48

 

02H

2

-24

 

07H

7

-54

 

03H

3

-30

 

08H

8

-60

 

04H

4

-36

 

 

 

 

 

 

Example: Setting the input sensitivity of Input Channel 5 to –24 dB.

ACH, 02H, 04H, 02H

5.11. Phantom Power ON/OFF Setting

Sets the phantom power of Input channel to ON or OFF. 9000Series Amplifier responds with the same data as that received.

Note: Command cannot be received during power off.

87H, 02H, <Channel Number>, <OFF/ON>

<Channel Number>

00H - 07H (Input channel 1 - 8)

<OFF/ON>

00H: PHANTOM OFF

01H: PHANTOM ON

Example: Setting the phantom power of Input Channel 1 to ON. 87H, 02H, 00H, 01H

Page 19 of 24

Page 19
Image 19
Vax RS 232C manual Input Sensitivity Table, Input Sensitivity Setting, Phantom Power ON/OFF Setting