8. Troubleshooting
8.1 Troubleshooting
To troubleshoot your vacuum, see Table
Note: Always turn off the vacuum and disconnect the power cord from the electrical outlet before troubleshooting or servicing.
Table 8-1 Troubleshooting Your Vacuum
Problem | Possible Cause | Possible Solution | Reference | |
|
|
|
| |
| Switch not “ON” on Canister. | Toggle switch to “ON” on canister. | 6.3 | |
|
|
|
| |
Vacuum cleaner | Switch not “ON” on Hose/Handle. | Toggle switch to “ON” on hose handle. | 6.4 | |
will not run, or | No voltage at wall electrical outlet. | Try a different electrical outlet or contact a | N/A | |
runs intermittently | licensed electrician. | |||
|
| |||
|
|
|
| |
| Power cord not securely plugged in. | Plug power cord securely in wall electrical outlet. | 6.2 | |
|
|
|
| |
| Filter(s) are dirty or clogged. | Clean or replace filters. | ||
|
|
|
| |
| Dirt Cup is full. | Empty Dirt Cup. | 7.1 | |
|
|
|
| |
Poor Suction: | Blockage in Sanitizing Power Head | Carefully remove blockage. | N/A | |
Syphon, Wand or Hose. | ||||
Canister / |
|
| ||
|
|
| ||
| Slide Suction Control Slider to maximum position |
| ||
Sanitizing Power |
|
| ||
Head | Suction power controls open. | and Airflow Selector to closed position; set Floor | ||
|
| Selector for bare floors. |
| |
| Loose hose or wand connection. | Check that all hose and wand connections are | ||
| secured properly. | |||
|
|
| ||
|
|
|
|
29