Defiant Woodburning Stove
Distance from the Center of the Flue Collar to the Wall
The information on this page is helpful in planning stove placement, particularly in those installations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must adhere to the guidelines in the clearance chart on Page 12.
Note that rear dimensions differ for installations with 6” or 8” chimney connectors.
Defiant With Rear Heat Shield only
Unprotected Surfaces |
|
| Protected Surfaces | ||||
Parallel Installations | Corner | Parallel Installations |
| Corner | |||
| |||||||
Installations |
| Installations | |||||
|
|
|
|
|
| ||
Side (A) | Rear (B) | Corner (C) | Side (D) |
| Rear (E) |
| Corner (F) |
|
| ||||||
|
|
|
|
|
|
|
|
39¹⁄₂” (1003mm) | 6” chimney: | 28” (710 mm) | 29¹⁄₂” (710 mm) |
| 6” chimney: |
| 25” (635 mm) |
| 27” (685 mm) |
|
|
| 21” (535 mm) |
|
|
| 8” chimney: |
|
|
| 8” chimney: |
|
|
| 28” (710 mm) |
|
|
| 22” (560 mm) |
|
|
|
|
|
|
|
|
|
|
Defiant With Rear Heat Shield and Shielded Connector:
Side (A)
39¹⁄₂” (1003mm)
Rear (B)
6” chimney: 17” (432 mm)
8” chimney:
18” (457 mm)
Corner (C)
28” (710 mm)
Side (D)
29¹⁄₂” (710 mm)
Rear (E)
6” chimney: 17” (432 mm)
8” chimney:
18” (457 mm)
Corner (F)
25” (635 mm)
Defiant With Rear Heat Shield and
|
|
|
|
|
|
|
| Side (A) | Rear (B) | Corner (C) | Side (D) | Rear (E) | Corner (F) |
|
|
|
|
|
|
|
| 39¹⁄₂” (1003mm) | 6” chimney: | 28” (710 mm) | 29¹⁄₂” (710 mm) | 6” chimney: | 25” (635 mm) |
|
| 17” (432 mm) |
|
| 15” (381 mm) |
|
|
| 8” chimney: |
|
| 8” chimney: |
|
|
| 18” (457 mm) |
|
| 16” (406 mm) |
|
|
|
|
|
|
|
|
A
*
BC
*
D
EF
*This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page: 34” (865 mm) in the United States and 36” (914 mm) in Canada.