Vermont Casting 1945 Defiant With Rear Heat Shield only, Defiant Woodburning Stove, Corner

Models: 1945

1 40
Download 40 pages 14.3 Kb
Page 16
Image 16
Defiant With Rear Heat Shield only

Defiant Woodburning Stove

Distance from the Center of the Flue Collar to the Wall

The information on this page is helpful in planning stove placement, particularly in those installations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must adhere to the guidelines in the clearance chart on Page 12.

Note that rear dimensions differ for installations with 6” or 8” chimney connectors.

Defiant With Rear Heat Shield only

Unprotected Surfaces

 

 

Protected Surfaces

Parallel Installations

Corner

Parallel Installations

 

Corner

 

Installations

 

Installations

 

 

 

 

 

 

Side (A)

Rear (B)

Corner (C)

Side (D)

 

Rear (E)

 

Corner (F)

 

 

 

 

 

 

 

 

 

 

39¹⁄” (1003mm)

6” chimney:

28” (710 mm)

29¹⁄” (710 mm)

 

6” chimney:

 

25” (635 mm)

 

27” (685 mm)

 

 

 

21” (535 mm)

 

 

 

8” chimney:

 

 

 

8” chimney:

 

 

 

28” (710 mm)

 

 

 

22” (560 mm)

 

 

 

 

 

 

 

 

 

 

Defiant With Rear Heat Shield and Shielded Connector:

Side (A)

39¹⁄” (1003mm)

Rear (B)

6” chimney: 17” (432 mm)

8” chimney:

18” (457 mm)

Corner (C)

28” (710 mm)

Side (D)

29¹⁄” (710 mm)

Rear (E)

6” chimney: 17” (432 mm)

8” chimney:

18” (457 mm)

Corner (F)

25” (635 mm)

Defiant With Rear Heat Shield and Double-wall Connector:

 

 

 

 

 

 

 

 

Side (A)

Rear (B)

Corner (C)

Side (D)

Rear (E)

Corner (F)

 

 

 

 

 

 

 

 

39¹⁄” (1003mm)

6” chimney:

28” (710 mm)

29¹⁄” (710 mm)

6” chimney:

25” (635 mm)

 

 

17” (432 mm)

 

 

15” (381 mm)

 

 

 

8” chimney:

 

 

8” chimney:

 

 

 

18” (457 mm)

 

 

16” (406 mm)

 

 

 

 

 

 

 

 

Parallel Installations A CornerInstallations

*

BC

Manual background*Manual background

Manual background D Manual backgroundManual background

EF

*This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page: 34” (865 mm) in the United States and 36” (914 mm) in Canada.

16

30001693

Page 16
Image 16
Vermont Casting 1945 Defiant With Rear Heat Shield only, Defiant Woodburning Stove, Unprotected Surfaces, Corner