48"48"
(1220mm) (1220mm)
48" | 48" |
(1220mm) | |
(1220mm) |
|
ST497
Fig. 16 Parallel installation, vertical chimney connector, two wall shields. Reduced clearances for both rear and side walls. Wall shields may meet at corner if desired. Shielding for con- nector is centered behind connector.
48" (1220mm)
48" | 48" |
(1220mm) | (1220mm) |
ST498
Fig. 17 Parallel installation with rear wall
Refer to “Special Installations.”
Defiant Woodburning Stove
48" | 48" |
(1220mm) | (1220mm) |
48" | 48" |
(1220mm) | (1220mm) |
| ST499 |
Fig. 18 Corner installation, vertical chimney connector, two wall shields. Reduced side clearances. Wall shield MUST meet at corner.
Stove Heat Shields
The Vermont Castings Defiant Rear Heat Shield, shown below, is one way to reduce the clearance to the rear wall. The rear heat shield can be installed in any set- ting. However, since the chimney connector also radi- ates heat toward the wall, you must use a chimney con- nector shield whenever you use the rear heat shield.
Clearance reductions with the rear heat shield apply only to the wall to the rear in parallel installations. Nei- ther the side clearance requirement nor the clearance requirement in corner installations may be reduced.
Flue Collar Heat
Shield
Rear Heat
Shield
Bend
Spacers
Truss Head
Phillips Screws
KT287
Fig. 19 Defiant rear heat shield with flue collar heat shield for top exit configuration.
30001693 | 15 |