Dutchwest
Distance from Center of Flue Collar to Wall in
Dutchwest Convection Heater Model 2479
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col- lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the wall protector.
B A C
C
E | D |
F |
F |
ST427
| UNPROTECTED SURFACES | PROTECTED SURFACES |
| ||||
|
|
| Corner |
|
| Corner |
|
| Parallel Installations | Installations | Parallel Installations | Installations |
| ||
Chimney Connector | Side | Rear | Corner | Side | Rear | Corner |
|
Listed, Approved | (A) 34¹⁄₂” | (B) 12¹⁄₂” | (C) 21” | (D) 22¹⁄₂” | (E) 12” | (F) 20¹₂” |
|
(846 mm) | (318 mm) | (533 mm) | (572 mm) | (305 mm) | (521 mm) |
| |
flue collar shield |
|
|
|
|
|
|
|
Single wall, with | (A) 29¹⁄₂” | (B) 12¹⁄₂” | (C) 21” | (D) 22¹⁄₂” | (E) 9¹⁄₂” | (F) 18¹⁄₂” |
|
Connector heat shields | (749 mm) | (318 mm) | (533 mm) | (572 mm) | (241 mm) | (570 mm) |
|
and flue collar shield |
|
|
|
|
|
|
|
Single wall with no | (A) 35¹⁄₂” | (B) 23¹⁄₂” | (C) 30” | (D) 22¹⁄₂” | (E) 17¹⁄₂” | (F) 25” |
|
heat shields | (902 mm) | (967 mm) | (762 mm) | (572 mm) | (445 mm) | (635 mm) |
|
|
|
|
|
|
|
|
|
14 | 30002291 |