Vermont Casting 2490 Alcove Installations, Construction Requirements, 2000893

Models: 2490

1 32
Download 32 pages 15.33 Kb
Page 16
Image 16
Alcove Installations

Resolute Acclaim Woodburning Stove

Alcove Installations

Because of their restricted air flow and heat retention characteristics, specific construction requirements and special clearances apply to installations into alcoves. No stove or chimney connector heat shields are used in alcove installa- tions. Bottom heat shield requirements remain the same as for other installations.

ALCOVE INSTALLATION OF THE RESOLUTE ACCLAIM IS NOT PERMITTED IN CANADA.

Construction Requirements

Showing noncombustible ceiling framing and maximum and minimum permitted dimensions.

 

ST504

Fig. 22

Cutaway perspective of alcove installation.

Joist Shield (supplied by chimney manufac- turer)

1” air gap top and bottom, on both sides and back wall

Metal

Stud

Combustible facing may overlap metal studs by only 1”

7/16” Durock© (or equivalent)

R E S O L U T E

Acclaim

ST609

Existings

 

24"

Combustible Framing

 

 

 

11"

Metal studs

 

Min.

support 7/16”

 

 

Durock© (or

 

36"

equivalent)

 

 

Min.

ceiling

 

 

 

 

14¹⁄₄"

 

 

48" Min.

ST505

 

 

Fig. 23 Reflected ceiling plan.

 

 

Fig. 25 Alcove side section.

Ceiling sup- port package extends 2” below Durock© (or equivalent) ceiling

1” air gap,

 

62" Min.

top, bottom,

65"

to Alcove

on both sides

 

and back wall

 

Ceiling

NOTE: From

 

 

36"

(914mm) Use recommended Max. floor protection

48" (1219mm) Min. Construction RequirementsManual background

7/16” Durock© (or equivalent) spaced 1” off wood studs on noncombustible spacers

ST502

62” to 65” must

be covered by

a noncombus-

tible material.

ST610

Fig. 26 Front section: 65” minimum clearance to combus- tibles on front face. Combustible facing may overlap metal

Fig. 24 Floor plan. Sheetrock on front face butts to Durock© (or equivalent) alcove lining.

studs by only 1”. It should not extend below the height of the noncombustible ceiling.

16

2000893

Page 16
Image 16
Vermont Casting 2490 Alcove Installations, Construction Requirements, Resolute Acclaim Woodburning Stove, 2000893